background image

1. Unscrew the lancing device tip

and insert a  lancet firmly into

the  carrier.

2.Pinch the lancet and twist 

off the protective cover. Do

not discard the cover.

3.The tip of the lancing device offers

5 different  levels of skin penetration, 

to select the best depth: Use1-2 for

soft or thin skin, 3for average skin, 

4-5 for  thick or calloused skin.

4. Hold the tip in one hand and pull 

on the sliding  barrel with the other 

hand. Pull the end apart and you will 

feel a click. This indicates that the

lancing device is in a locked position

ready for lancing.

5. Release the sleeve.  It will automati

cally contract and move back to its

original position near the trigger

hub.

6. Place the lancing device against

the tip of the finger. Press the

trigger button. Your blood sample

should now be ready to be applied

on the test strip.  Lift the lancing

device out and away.

Collecting a Drop of Blood

Alarm

INPUT the number of desired ALARMS. 

Enter button.

# Available to set Max 5 alarm function and new 3 average dates.

Alarm

<Caution>

1. Without setting the date properly, the average glucose level and the results in

memory will not show proper values. It is recommended to set the meter before
use and when new batteries are installed.

2. Yon can

t test your blood glucose while in the setting mode.

3. You will be unable to test while setting up your meter.

Year Mode : From 2006 to 2099

18

myglucohealth

TM

Blood Glucose Monitoring System

myglucohealth

TM

Blood Glucose Monitoring System   19

Summary of Contents for EHS-MGEU00001

Page 1: ......

Page 2: ...myglucohealthTM Blood Glucose Monitoring System 3 ...

Page 3: ...ert myglucohealthTM Strip The code number is automatically entered 2 Select activities related to the test result by press button or button When it is selected press the but ton 2 3 3 Apply sample until confir mation window is com pletely filled before the meter begins to count down 4 Test results in 3 seconds 4 Before using myglucohealthTM meter read all instructions in this manual and the additi...

Page 4: ...r and maintenance 30 31P Battery installation 32P Troubleshooting 33P 36P Specifications 37P 39P Blood Glucose Conversion Table mmol L to mg dL 40P 1 myglucohealthTM meter 2 myglucohealthTM test strips 3 Lancing Device 4 Lancets 5 Operation Manual 6 Warranty Registration Card 7 Patient Logbook 8 Two 1 5V Alkaline battery AAA Size 9 Carrying Case Check your myglucohealthTM system to make sure that ...

Page 5: ...setting data and scrolls result PAIR SEND Bluetooth function pairing sending data 6 Product label 7 Battery cover Low battery warning Strip code Blood drop for test Alarm Before having a meal After having a meal After sports activity After taking drugs Control solution test Temperature Date Test result unit Time Delete LCD Display myglucohealthTM Blood Glucose Meter 8 myglucohealthTM Blood Glucose...

Page 6: ...test strip Do not bend cut or alter the myglucohealthTM strip 7 myglucohealthTM test strips are for single use only 8 Keep the test strip bottle away from children 9 Please refer to the user s manual for myglucohealthTM blood glucose test strip for additional information Automatic code recognition myglucohealthTM Test Strip 10 myglucohealthTM Blood Glucose Monitoring System myglucohealthTM Blood G...

Page 7: ...r and the Test strips are working together as a system and that you are performing the test correctly It is very important that the control solution is used routinely to make sure that you receive accurate results The myglucohealthTM Control Solution contains a measured amount of glucose that reacts with the myglucohealthTM Control Solution Test Strips Compare your control solution test results wi...

Page 8: ...t range Comparing Control solution Results If the Control Solution test results fall outside the range repeat the test Out of range results may be caused by one or more of the following reasons Error in performing the test Failure to shake the control solution vial well enough must shake vigorously Failure to discard the first drop of control solution Expired or contaminated control solution Meter...

Page 9: ...Beep sound to alert when function is set date time test unit of results and the ability to designate three unique data averages Set the Meter year Press and release either or buttons to set the year Enter button date time Press and release either or buttons to set the date and time Enter button Year power on date time 16 myglucohealthTM Blood Glucose Monitoring System myglucohealthTM Blood Glucose...

Page 10: ...l position near the trigger hub 6 Place the lancing device against the tip of the finger Press the trigger button Your blood sample should now be ready to be applied on the test strip Lift the lancing device out and away Collecting a Drop of Blood Alarm INPUT the number of desired ALARMS Enter button Available to set Max 5 alarm function and new 3 average dates Alarm Caution 1 Without setting the ...

Page 11: ...d reinsert the test strip 4 Avoid testing under direct sunlight for a more accurate test result 5 If you apply your blood sample too early error message will appear on LCD refer to p35 Testing Your Blood Before testing be sure to read carefully this section and test strip instruction for use found in the test strip box carefully Make sure you have all the necessary items to begin your test 1 myglu...

Page 12: ...is case the test procedure should start again from the beginning Testing Your Blood Testing Your Blood 22 myglucohealthTM Blood Glucose Monitoring System Step 2 Select activities related to the test result Select the activity based features press or button to select the activity that correlates with your result then press button Before having a meal After having a meal After taking medications Aft...

Page 13: ...stem Step 4 After beeping sound the test will begin automatically and your results will appear in 3 seconds It should begin counting down from 3 to 1 second on the LCD display window The LCD window will display the result of your blood glucose level temperature and time Record the result value in your logbook When you pull out the test strip the meter will turn off automatically Caution 1 If the t...

Page 14: ...calculated and saved These values can be recalled in the LCD date display at any time The newest result will replace the oldest beyond the 250 data stored Press button shortly The newest data appears during setup refer to p21 You can check your individual data of the latest 3days and previously set up 3 dif ferent types of average days 7d 14d 21d through pressing button Press button displaying the...

Page 15: ...hen myglucohealth meter is pair ing with mobile phone And then If you press ⓛ button meter goes into standby status and LCD window will turn off Transfer Test Results myglucohealthTM Bluetooth function You need a Bluetooth mobile phone which has SPP a b Profiles function SPP Serial Port Profile a Initiator b Acceptor JAVA application is built in the mobile phone and provides UI according to the ki...

Page 16: ...on after data transmission and LCD window will be turned off Transfer Test Results 30 myglucohealthTM Blood Glucose Monitoring System Step 4 Testing your Blood Step 5 Sending glucose data Pressing send button while display blood glucose test result on LCD window LCD window will display bt and st 2 Within minutes LCD window will display st 3 when myglucohealthTM meter is connected to mobile phone a...

Page 17: ...e If necessary rubbing alcohol can be used to wipe away dirt on the outer surface of the meter Do not use chemical solutions such as benzol or acetone since both of these solutions can harm and damage the meter surface When cleaning the meter with rubbing alcohol DO NOT pour directly onto the meter but use a cloth soaked with a small amount of alcohol After cleaning the meter dry completely at a c...

Page 18: ...blink with Sun Avoid to the direct sunlight and retest Message Casued by What to do Battery installation 34 myglucohealthTM Blood Glucose Monitoring System The battery shortage mark will appear in the upper left corner of the LCD screen to alert you when the battery power is running low indicating a new battery is needed The myglucohealthTM meter will not power on when the battery power is exhaust...

Page 19: ...r for assistance Message Casued by What to do Troubleshooting 36 myglucohealthTM Blood Glucose Monitoring System The blood sample was applied before the test symbol blood insertion pic ture appeared on thedisplay Repeat the test with new test strip Apply blood only after the test symbol blood inser tion picture appears on the display The ambient tem perature is too low Place the meter within the o...

Page 20: ...Sample volume Test Range Reading time Calibration Altitude Operating Temperature Operating Humidity Strip storage temperature Display Type Dimension Weight Power rating Battery Life PC communications port Capillary whole blood 0 3ul 0 6 33 3 mmol L 3 seconds Plasma Equivalent 3048 m 10 40 10 90 2 30 LCD 52 2 X 98 5 X 23 4 mm 74 5g battery include 3 V Alkaline Battery 1 5V AAA Size X 2 Running 2 00...

Page 21: ... mg dL mmol L mg dL Test principle 40 myglucohealthTM Blood Glucose Monitoring System The glucose enzyme oxidase on the test strip reacts specifically with the blood glucose The current generated is converted and displayed as blood glucose level The myglucohealthTM system is plasma calibrated to allow easy compari son of results with laboratory methods Blood glucose meter which are calibrated agai...

Page 22: ...fications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment EC R TTE EC R TTECE Marking Indication of the intended use of the equipment Declaration of Conformity DoC Blood Glucose Monitoring System with built in Bluetooth function For self testing only Hereby infopia Co Ltd declares that this MygllucohealthTM Blood Glucose Monit...

Page 23: ......

Reviews: