MYLEXRAIDMIB Object Definitions
A-26
Disk Array Controller Software Kit User’s Manual
Battery Backup Unit Information Group
This object is used to obtain information about the Battery Backup Unit
(BBU).
Notes:
• a10ControllerNumber is the index for any search operations against
this object.
• This is a READ-ONLY object. No SET operations are allowed.
• A GET operation returns information about the object whose MIB ID
is in the query.
• A GETNEXT operation returns the object’s information which is next
to the MIB ID given in the query.
• Controller numbers start at 0.
Table A-12. Battery Backup Unit Information Group
Table object
Data
Type
Description
a10ControllerNumber
1.3.6.1.4.1.1608.1.1.1.10.1.1
Integer
References a particular
controller by its controller
number
a10OperationalState
1.3.6.1.4.1.1608.1.1.1.10.1.2
Integer
The operational state of the
BBU
a10BatteryType
1.3.6.1.4.1.1608.1.1.1.10.1.3
Integer
The battery type
a10CurrentPowerInHours
1.3.6.1.4.1.1608.1.1.1.10.1.4
Integer
Current battery power in hours
a10MaximumPowerInHours
1.3.6.1.4.1.1608.1.1.1.10.1.5
Integer
Maximum battery power in
hours
a10ThresholdValueInHours
1.3.6.1.4.1.1608.1.1.1.10.1.6
Integer
Battery threshold value in hours
a10ChargeLevelInPercentage
1.3.6.1.4.1.1608.1.1.1.10.1.7
Integer
Current charge level of the
battery (%)
a10Version
1.3.6.1.4.1.1608.1.1.1.10.1.8
Integer
The battery hardware version
Summary of Contents for Disk Array controller Software Kit 2.01
Page 2: ......
Page 6: ......
Page 12: ...xii Disk Array Controller Software Kit User s Manual...
Page 20: ...Requirements 1 8 Disk Array Controller Software Kit User s Manual...
Page 124: ...Shell Utility for UnixWare 5 20 Disk Array Controller Software Kit User s Manual...
Page 154: ...Installing TCP IP Windows NT B 4 Disk Array Controller Software Kit User s Manual...
Page 171: ......