SCO UNIX
Manual No. 771929
4-5
4
S
C
O
U
N
I
X
8. From this point forward, follow the standard procedure for SCO UNIX
installation. Make sure the entire Extended Utilities of SCO UNIX are
installed. Near the end of the installation, the following description is
displayed:
The following packages are on this disk:
NAME DESCRIPTION
mdac Mylex DAC960-P/DAC960-E/DAC960-M RAID
controller driver
Please enter the names of the packages you wish to
install, or 'q' to quit
[default: mdac]:
9. Press the Enter key to continue. The system displays several messages.
After the system has completed its installation, you will see the
following message:
NOTICE: Flushing DAC960
[x] 0 cache... done
** Safe to Power Off **
- or -
** Press any Key to Reboot **
where [x] is the base model of the controller (P, E, or M).
10. This concludes the installation of SCO UNIX and the Mylex Disk
Array Controller driver. Reboot the operating system from the System
Drive that was just installed.
Installing Additional Mylex Disk Array Controllers
The driver for both the primary controller and any secondary controllers are
installed simultaneously as a part of the previous SCO UNIX installation. No
further procedures are required in order to use additional Mylex Disk Array
Controllers as secondary controllers in the installation.
Adding System Drives
The recommended method for creating UNIX file systems on System Drives
is through the SCO UNIX mkdev hd command. Follow the instructions in the
SCO UNIX documentation for adding a hard disk.
Summary of Contents for Disk Array controller Software Kit 2.01
Page 2: ......
Page 6: ......
Page 12: ...xii Disk Array Controller Software Kit User s Manual...
Page 20: ...Requirements 1 8 Disk Array Controller Software Kit User s Manual...
Page 124: ...Shell Utility for UnixWare 5 20 Disk Array Controller Software Kit User s Manual...
Page 154: ...Installing TCP IP Windows NT B 4 Disk Array Controller Software Kit User s Manual...
Page 171: ......