SCO UNIX
Manual No. 771929
4-9
4
S
C
O
U
N
I
X
4. Relink the kernel:
#cd /etc/conf/cf.d
# ./link_unix
5. Reboot the system.
6. Make sure you are in single-user mode (init 1), then install the Mylex
mdac drivers by running the installpkg utility. Insert the “Software Kit
SCO OpenServer Driver diskette.”
# init 1
# installpkg
7. When the message prompt asks for a package name, type mdac.
Please enter the names of the packages you
wish to install, or q to quit: mdac
8. Rebuild SCO UNIX kernel.
# cd /etc/conf/cf.d
# ./link_unix
9. Reboot the system to invoke the new kernel.
10. Run mkdev hd to configure the hard disks (system drives) on the
controller.
• Enter
mdac
for package name
• Select the target IDs and LUN numbers until all controllers and
system drives are configured (refer to Table 5-1).
• Select Y to relink kernel
11. Reboot the system to invoke the new kernel. Run mkdev hd again to
prepare storage space for the UNIX filesystem. Be sure to enter the
same numbers entered in Step 10 above for each system drive. A
partition table will be displayed and you will be prompted to enter the
filesystem size in cylinders. For controller drive mapping, 1 cyl = 2MB.
Summary of Contents for Disk Array controller Software Kit 2.01
Page 2: ......
Page 6: ......
Page 12: ...xii Disk Array Controller Software Kit User s Manual...
Page 20: ...Requirements 1 8 Disk Array Controller Software Kit User s Manual...
Page 124: ...Shell Utility for UnixWare 5 20 Disk Array Controller Software Kit User s Manual...
Page 154: ...Installing TCP IP Windows NT B 4 Disk Array Controller Software Kit User s Manual...
Page 171: ......