Operating Systems and Drivers
Manual No. 775031
9
To install GAM server, refer to the Disk Array Controller Software Kit
Installation Guide and User Manual (P/N 771929). To install the GAM
client, (on a client Windows 95 or NT workstation) refer to the Global Array
Manager Client Software Installation Guide and User Manual (P/N
771961).
Installing the Mylex Disk Array Controller into an Existing
NetWare 4.11/4.2 System
If NetWare 4.11/4.2 is already installed and you wish to add a Mylex Disk
Array Controller later, the controller will be a secondary (non-bootable)
controller. After installing the controller hardware and configuring a disk
array, follow the procedure below to add the necessary controller drivers.
1. With NetWare Server 4.11/4.2 loaded and running, load the NetWare
program INSTALL.NLM by typing the following at the console
prompt:
: load install
and press <Enter>.
2. Choose “Driver Options” in the Installation Options menu.
3. Choose “Configure disk and storage device drivers” in the Driver
Options menu.
4. Choose “Select an additional driver” in the Additional Driver Actions
menu.
NetWare scans for controllers that do not have drivers already loaded.
5. At the “Select a driver” box, press <Ins> to choose to install an unlisted
driver.
6. Insert the NT/NW drivers diskette into the diskette drive.
7. Press <F3> to specify the path of the NetWare driver you’re about to
install.
8. Change the path line to read:
A:\nw
and press <Enter>. NetWare scans for drivers on the floppy diskette in
the specified path.