AC•THOR®9s Assembly Instructions, Version 200910 9
•
Do not install the device in an environment contaminated with
ammonia.
•
Do not install the device in a dusty environment.
•
The ventilation holes of the housing must not be covered.
•
Avoid exposure to high temperatures (> 40 °C), low temperatures
(< 0 °C) or direct sunlight during storage and operation.
•
The AC•THOR®9s must be connected to a nominal voltage of 3 x
230 V AC, 50/60 Hz. The neutral conductor is necessary!
•
Protection of the mains connection for the AC•THOR®9s may not
exceed 16 A per phase (tripping characteristic B or C).
5.
Connections overview
Summary of Contents for ESW AC-THOR 9s