MPRT MS 

PROGRAMMABLE ROOM THERMOSTAT

The MPRT MS is a programmable room thermostat. It senses the 
room temperature and if heat is called for, it activates the heating.

WIRING THE MPRT MS.

The MPRT MS is wired directly to the
heating equipment and powered
directly from the main voltage supply.

MPRT MS

INSTALLATION INSTRUCTION

LOCATING THE ROOM UNIT

The MPRT MS is mounted using the two screws provided.
WHEREVER the Room Unit is mounted/used it should be out of 
direct sunlight, out of draughts, and clear of any heat source (e.g. 
radiators, fires or electronic equipment). For optimum use the unit 
should be sited between 1 and 1.5metres from the floor.

OK

H

M

L

HEAT
TIMES

PRESS TO ALTER YOUR HEATING TIMES

PRESS TO DEACTIVATE HEATING, OR HOLD

FOR 5 SECONDS FOR MANUAL OVERRIDE

PRESS FOR 1 HOUR OF HIGH TEMPERATURE

PRESS TO ALTER YOUR “HIGH” TEMPERATURE

PRESS BOTH TOGETHER TO SET/VIEW CLOCK

PRESS TO ALTER YOUR “MID” TEMPERATURE

PRESS TO ALTER YOUR “LOW” TEMPERATURE

OFF
MAN

1 Hr

High Setting

Current

Temp

0

2

4

6

8 10 12 14 16 18 20 22 24

OK

H

M

L

HEAT
TIMES

PRESS TO ALTER YOUR HEATING TIMES

PRESS TO DEACTIVATE HEATING, OR HOLD

FOR 5 SECONDS FOR MANUAL OVERRIDE

PRESS FOR 1 HOUR OF HIGH TEMPERATURE

PRESS TO ALTER YOUR “HIGH” TEMPERATURE

PRESS BOTH TOGETHER TO SET/VIEW CLOCK

PRESS TO ALTER YOUR “MID” TEMPERATURE

PRESS TO ALTER YOUR “LOW” TEMPERATURE

OFF
MAN

1 Hr

High Setting

Current

Temp

0

2

4

6

8 10 12 14 16 18 20 22 24

(1.0 - 1.5) m

Release the MPRT MS from its 

base by pressing at the arrow. 

STEP 1.

Remove terminal covers by removing terminal screws.

STEP 2.

Thread control and power input wires through the knock-outs and 
attach base plate to the wall.

STEP 3.

Connect control wires to terminals 2 and 3.
Connect power input wires to terminals 4 and 6.

PRECAUTIONS AGAINST ELECTRIC

 SHOCK HAZARD.

Disconnect mains supply before moving cover.

Installation and maintenance must be carried out by suitably 

qualified personnel and in accordance with current IEE wiring 

regulations.

Do not mount to unearthed metal or metalised surfaces.

Fixed wiring installation must be employed. A class ’A’ switch, 
(having contact seperation of at least 3mm in all poles) must be 
incorporated in the fixed wiring as a means of disconnecting the 
supply. Use a fuse rated at least 3 amps to protect the system.

1 2 3

To heating

equipment

c

WIRING THE MPRT

To heating

equipment

MPRT Back Cover 

1

2
3

The MPRT is wired directly to the

heating equipment.

To heating

equipment

1

5

1

2

3

5

4

6

1
2
3

0

C

Power input

230 V

AC 50Hz 

Live

Neutral

4
5
6

1 2 3

To heating

equipment

c

WIRING THE MPRT

To heating

equipment

MPRT Back Cover 

1

2
3

The MPRT is wired directly to the

heating equipment.

To heating

equipment

1

5

1

2

3

5

4

6

1
2
3

0

C

Power input

230 V

AC 50Hz 

Live

Neutral

4
5
6

1 2 3

To heating

equipment

c

WIRING THE MPRT

To heating

equipment

MPRT Back Cover 

1

2
3

The MPRT is wired directly to the

heating equipment.

To heating

equipment

1

5

1

2

3

5

4

6

1
2
3

0

C

Power input

230 V

AC 50Hz 

Live

Neutral

4
5
6