31
settings. Never change the stove type during the operation off the
device.
Reset Service Time
to zero.
Thermostat ON/OFF
engages or disengages the external thermostat
function. All air stoves (TA) and the hydro stove (TS) have OFF the
thermostat in order to operate with their own in the room. Boiler as
the
THP and MLS
has
ON
the thermostat in order to connect a room
thermostat.
Pellet Level Sensor
is always in OFF state. It is available as extra
equipment and in that case will be engaged by the factory.
4.3.5.3
-
ECO MENU
Table 22
Entering to
ECO menu
you can set the parameters according to
Table 22
as
below:
ECO function
is by default choice in order
to operate the stove/boiler
on the basis of economy.
Waiting On
: Set’s the waiting time that the stove boiler will start
when the demand of the room temp is on. A minimum set time is
selected in order to avoid the “open/close” of the thermostat.
Waiting Off
: Set’s the waiting time that the stove/boiler will go to
shutdown when the room temperature is achieved. A minimum set
time is selected in order to avoid the immediate shutdown; given time
to the next demand of the thermostat. The stove/boiler goes to
Power Level 1 during that time.
To maximize the benefit of the ECO function the time waiting Off set;
should be adjusted to each installation according to the needs.
4.3.5.4
-
FAN MENU (Air Stoves or TS-A model)
MENU
SUB MENU
SUB
VALUE
SETTINGS
Technical
Menu
Eco Menu
Waiting On
0 – 60 min
5 min
Waiting Off
0 – 60 min
15 min
Delta Temp.
0 – 10
°
C
1
°
C