37
pellet to ON state. If during that time the flame is lost or the fumes
temp. drops from the Fumes OFF set temp. appears the alarm A02.
Thermocouple
always in OFF.
4.3.5.10 – CLEANING MENU (Burner pot cleaning)
Table 30
Entering to
Cleaning Menu
you can set the parameters according to
Table 30
as below
:
Duration 1
sets the period in seconds that the cleaning procedure
starts.
Duration 2
sets the time in seconds that the cleaning is on.
Threshold
sets the Power level and above that the cleaning process
will activate.
At the cleaning process the extractor fan revs to maximum rpm
(2700rpm) in order to clean the burner pot.
.
MENU
SUB MENU
SUB
VALUE
SETTINGS
Technical
Menu
Cleaning Menu
Duration 1
0 -2000 s
1800 s
Duration 2
0 -60 s
10 – 20 s
Threshold
1 - 5
2 - 5