WARNING

 

DO NOT OPERATE THIS TOOL WITHOUT

 

PROTECTIVE EARTH CONNECTED

 

 

 

 

 

 

 

  1

This tool should be grounded while in use to protect the operator from electric shock. NOTICE! To ensure the grounding result, 

the grounding conductor of the power cord must be well connected with the grounding terminal of power facility. This tool is 

equipped with grounding conductors. The Green (or Green and Yellow) conductor in the Power Cord is the grounding wire. 

Never connect Green (or Green and Yellow) to a live terminal. The grounding wires in this tool can not only earth the electric 

leakage safely, but also can eliminate ESD-the electrostatic that tool occurred while in use. 

2

The grounding is the most important task a user. Periodically, depends on the working condition and circumstance, for 
maintaining a good function the user has to check the grounding condition every 3~6 months by an electric meter and following 

simple steps; Set the Ohm meter to level R*100(Ohm). Touching 2 test rods (“

”) together and reset the meter to “0”. 

Using the Red(“

”) rod to touch the Grounding wire on the Plug of controller’s cord, and the Black(“

”) rod to the end of Bit 

Head. It stands for the grounding is normal if the meter is read as close as to “0”. For getting a normal indication on the meter 

while in testing, need to press the test rods firmly to the testing objects. 

3

The instrument QC of the tool is performed before the tool ex-factory. The grounding continuity test is conducted by input 26A 
voltage to the end of earth terminal, and subject to the resistance value lower than 0.3Ohm. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

       

  Grounding Instructions 

Summary of Contents for MY9-TR0206L

Page 1: ...ng to high torque series For safety consideration please collaborate it with Auxiliary Arm KP AUXA 2 DC TYPE Automatic Non Carbon Brush Series SAING EI CORP https www mytorqtools com Y2F168A 2E 005 MY9 TR0206L MY9 TR0309L MY9 TR0612L MY9 TR0206P MY9 TR0309P MY9 TR0612P ...

Page 2: ...ation enclosed Read all these instructions before placing tool in service or operation this tool and save these instructions It is the responsibility of the employer to place the information in this manual into the hands of the operator Failure to observe the following warnings could result in injury When using electric tools Basic safety precautions should always be followed to reduce the risk of...

Page 3: ...pment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries Rubber gloves and non skid footwear are recommended when working outdoors c Avoid accidental starting Ensure the switch is in the off position before plugging in Carrying power tools with your finger on the switch or plugging in power tools that have the switch...

Page 4: ...rson using only identical replacement parts this will ensure that the safety of the power tool is maintained Additional information shall be provided a Instruction for putting into use 1 Setting up or fixing power tool in a stable position as appropriate for power tools which can be mounted on a support 2 Assembly 3 Connection to power supply cabling fusing socket type and earthing requirements 4 ...

Page 5: ...t important task a user Periodically depends on the working condition and circumstance for maintaining a good function the user has to check the grounding condition every 3 6 months by an electric meter and following simple steps Set the Ohm meter to level R 100 Ohm Touching 2 test rods together and reset the meter to 0 Using the Red rod to touch the Grounding wire on the Plug of controller s cord...

Page 6: ...ype screwdriver When loosen a fastened screw please set Forward Reverse switch to Reverse If the screw is reversed thread screw please set Forward Reverse switch to Forward Follow the above operation after loosening the screw release the trigger to stop Push Start Type screwdriver When loosen a fastened screw please set Forward Reverse switch to Reverse If the screw is reversed thread screw please...

Page 7: ...set up the switch to Lo for slowest rotation It s possible that the uncompleted shut off occurs when the switch is setup to Lo and the presetting torque is more than 50 of torque range Please refer to the following table Maintenance and Inspection 1 The screwdriver must be operated in top condition one day working hour must be not more than eight hours cording to operating frequency and torque loa...

Page 8: ...center 3 SAING EI is not responsible for customer modification of tools for applications on which SAING EI was not consulted 4 Repairs should be made only by authorized trained personnel Consult your nearest MYTORQ authorized service center 5 It is the responsibility of the employer to place the information in this manual into the hands of the operator DO NOT ATTEMPT TO REPAIR THIS ELECTRIC SCREWD...

Page 9: ...9 TR0309P MY9 TR0612P Input voltage DC DC 40V Power Consumption 150 150 150 Torque N m hard joints 2 6 3 9 6 12 soft joints 80 2 4 8 3 7 2 6 9 6 Repeatable Torque Accuracy 5 Torque Adjustment Stepless Unloaded Rotation Speed R p m 10 1000 1000 880 Screw Size Dia Machine screw mm 4 0 5 0 5 0 6 0 8 Tapping screw mm 4 4 5 6 Weight Kg 1 03 Length mm 306 Model of Auxiliary Arm KP AUXA 2 Model of Side H...

Page 10: ...rew itself is different from the clamped conditions Understand the correlation between clamping torque values and the torque checker values perform the torque control properly 1 Please read the operation caution carefully before using our screwdriver and follow the safety information to use this power supplier 2 This model screwdriver must work with 6PIN power cord assembly and MYP40 1500 power su...