background image

 

                                                                                                                               

 

                   

 

                                       

 

 
 

 

 

 

WARNING!

 

Read all instructions Failure to follow all instructions listed below may result in electric shock fire and/or 

serious injure. The term “power tool” in all of the warning listed below refer to your mains operated (corded) power tool 
or battery operated (cordless) power tool. 

 

SAVE THESE INSTRUCTIONS 

1) Electrical Safety 

a) 

Keep work area clean and well lit.

 Cluttered and dark areas invite accidents. 

b) 

Do not operate power tools in explosive atmosphere, such as in the presence of flammable liquids, gases or 

dust.

 Power tools create sparks which may ignite the dust of fumes. 

c

) Keep children, and bystanders away while operating a power tool. 

Distractions can cause you to lose control. 

 

2) Electrical Safety 

a)

 Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any adapter plugs 

with earthed (grounded) power tools

. Unmodified plugs and matching outlets will reduce risk of electric shock. 

b)

 Avoid body contact with earthed or grounded surfaces such as pipes, radiators, ranges and refrigerators. 

There is an increased risk of electric shock if your body is earthed or grounded. 

c) 

Don’t expose power tools to rain or wet conditions. 

Water entering a power tool will increase the risk of electric 

shock. 

d) 

Do not abuse the cord. Never use the cord to carry, pulling or unplugging the power tool. Keep cord away 

from heat, oil, sharp edges or moving parts. 

Damaged or entangled cords increase the risk of electric shock. 

e) 

When operating a power tool outdoors, use an extension cord suitable for outdoor use.

Use of cord 

suitable for outdoor use reduces the risk of electric shock. 

 

3) Personal Safety 

a) 

Stay alert, watch what you are doing and use common sense when operating a power tool. Do not use power 

tool while you are tired or under the influence of drugs, alcohol, or medication. 

A moment of inattention while 

operating power tools may result in serious personal injury. 

b) 

Use safety equipment. Always wear eye protection. 

Safety equipment such as dust mask, non-skid safety shoes, 

hard hat, or hearing protection used for appropriate conditions will reduce personal injuries. 

Rubber gloves and non-skid footwear are recommended when working outdoors. 

c) 

Avoid accidental starting. Ensure the switch is in the off position before plugging in. 

Carrying power tools with 

your finger on the switch or plugging in power tools that have the switch on invites accidents. 

d) 

Remove any adjusting keys or wrench before turning the power tool on. 

A wrench or a key that is left attached 

to a rotating part of the power tool may result in personal injury. 

e) 

Do not overreach. Keep proper footing and balance at all times. 

This enables better control of the power tool in 

unexpected situations. 

f) 

Dress properly. Do not wear loose clothing or jewelry. Keep your hair, clothing, and gloves away from moving 

parts. 

Loose clothes, jewelry, or long hair can be caught in moving parts 

g)

 Secure work. 

Use clamps or a vice to hold the work. It is safer than using your hand and frees   

both hands to operate the tool.   

h) 

If devices are provided for the connection of dust extraction and collection facilities, ensure these are 

connected and properly used. 

Use of these devices can reduce dust related hazards. 

i) 

Use a safety device.   

   

Wear protective earmuffs to reduce personal injury. 

    Noise: 
    The typical A-weighted noise level . 
    .Sound pressure level(LpA): 84.8 dB(A) 
    .Sound power level(LwA): 95.38 dB(A) 
    Vibration: 
    The vibration total value . 
    .Vibration emission value ah (m/s²): 6.21 m/s2 
    .Uncertainty K (m/s²): 1.5 m/s2 

                  Important Safety Rules 

Summary of Contents for MYR-0206L

Page 1: ...rate it with Auxiliary Arm KP AUXA KP AUXA 500 Series DC TYPE Automatic Non Carbon Brush Series Anlidar INDUSTRIAL CO LTD http www anlidar com Y2F183A 3E 004 MYR 0206L MYR 0309L MYR 0412L MYR 0412LF MYR 0618L MYR 0618LF MYR 0825L MYR 0825LF MYR 1235L MYR 2050L MYR 0206P MYR 0309P MYR 0412P MYR 0412PF MYR 0618P MYR 0618PF MYR 0825P MYR 0825PF MYR 1235P MYR 2050P ...

Page 2: ...tion enclosed Read all these instructions before placing tool in service or operation this tool and save these instructions It is the responsibility of the employer to place the information in this manual into the hands of the operator Failure to observe the following warnings could result in injury When using electric tools Basic safety precautions should always be followed to reduce the risk of ...

Page 3: ...oing and use common sense when operating a power tool Do not use power tool while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating power tools may result in serious personal injury b Use safety equipment Always wear eye protection Safety equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate c...

Page 4: ... performed Use of the power tool for operations different from intended could result in a hazardous situation 5 SERVICE a Have your power tool serviced by qualified repair person using only identical replacement parts this will ensure that the safety of the power tool is maintained Additional information shall be provided a Instruction for putting into use 1 Setting up or fixing power tool in a st...

Page 5: ...d tool performance If a user doesn t mount the tool on an auxiliary arm he she needs to take the responsibility for any injury or product quality issue caused 9 Clamp fixed position for 3cm Nylon Fixed Wire The clamp fixed position for 3cm Nylon Fixed Wire is at 235mm start count from the top of the screwdriver flat surface for direct cable as shown in Figure 1 The clamp fixed position for 3cm Nyl...

Page 6: ...ly depends on the working condition and circumstance for maintaining a good function the user has to check the grounding condition every 3 6 months by an electric meter and following simple steps Set the Ohm meter to level R 100 Ohm Touching 2 test rods together and reset the meter to 0 Using the Red rod to touch the Grounding wire on the Plug of controller s cord and the Black rod to the end of B...

Page 7: ...will shut out automatically the power will shut off and the motor breaks immediately the screwdriver stop running 8 Trigger Start Type screwdriver When loosen a fastened screw please set Forward Reverse switch to Reverse If the screw is reversed thread screw please set Forward Reverse switch to Forward Follow the above operation after loosening the screw release the trigger to stop Push Start Type...

Page 8: ...you had set the tool will be stopped automatically To reset the tool by releasing the lever to the original position or releasing the bit from the screw head To return the screw set the changeover switch to R position Maintenance and Inspection 1 The screw driver must be operated in top condition one day working hour must be not more than eight hours 2 Please note don t let the motor get over heat...

Page 9: ... center 3 Anlidar is not responsible for customer modification of tools for applications on which Anlidar was not consulted 4 Repairs should by made only by authorized trained personnel Consult your nearest MYTORQ authorized service center 5 It is the responsibility of the employer to place the information in this manual into the hands of the operator DO NOT ATTEMPT TO REPAIR THIS ELECTRIC SCREWDR...

Page 10: ...R 0412L MYR 0618L MYR 0206P MYR 0309P MYR 0412P MYR 0618P Input voltage DC DC 40V Power Consumption 100 120 120 200 Torque N m 2 6 3 9 4 12 6 18 Repeatable Torque Accuracy 5 Torque Adjustment Stepless Unloaded Rotation Speed R p m 10 1200 900 600 370 Screw Size Dia Machine screw mm 4 0 5 0 5 0 6 0 8 10 Tapping screw mm 4 4 5 6 8 Weight Kg 1 25 Length mm 315 Model of Auxiliary Arm KP AUXA Model of ...

Page 11: ...ith the tool are available from MYTORQ catalogue MODEL MYR 0412LF MYR 0618LF MYR 0825L MYR 0825LF MYR 1235L MYR 2050L MYR 0412PF MYR 0618PF MYR 0825P MYR 0825PF MYR 1235P MYR 2050P Input voltage DC DC 40V Power Consumption 120 150 150 150 150 150 Torque N m hard joints 4 12 6 18 8 25 8 25 12 35 20 50 soft joints 80 4 9 6 6 14 4 8 20 8 20 12 28 20 40 Repeatable Torque Accuracy 5 Torque Adjustment S...

Page 12: ...screwdriver The clamping torque of screw itself is different from the clamped conditions Understand the correlation between clamping torque values and the torque checker values perform the torque control properly 1 Please read the operation caution carefully before using our screwdriver and follow the safety information to use this power supplier 2 This model screwdriver must work with 6PIN power ...

Reviews: