EV-040
Rev. 11
– 2018
English
18
Installing the chain counter
(see connection diagram)
Warning
ALWAYS DISCONNECT THE BATTERY PRIOR TO INSTALLATION.
The chain counter must be positioned so that the display will be easy to read. It should not be
exposed to direct sunlight.
Secure the instrument in place with the bracket provided, tightening the two screws using a
cross screwdriver.
For instructions on making electrical connections, see the attached diagram. The wires must
have a minimum cross section size of 1.5 mm².
Install a 3 A (ampere) fast safety fuse on the + wire of the battery. Do not use the voltage
generated by the engine battery set to provide power.
The instrument complies with EMC standards (EN55022) and must be positioned at a distance
of:
30 cm (~1 Ft) from the compass;
50 cm (~1.5 Ft) from radio equipment;
2 metres (~6.5 Ft) from radio transmitter equipment;
2 metres (~6.5 Ft) from the radar beam.