background image

NATIVE-C1 

T

ECHNICAL 

R

EFERENCE 

M

ANUAL 

V1.0 

 

 

 

C

HASSIS 

D

ESIGN

 

- 21 - 

Pin 

Signal 

Driven 

by 

Mating 

Pin 

Function 

on CU 

Pin 

Signal 

Driven 

by 

Mating 

Pin 

Function 

on CU 

6A 

TDI 

JTAG 

Agent 

First 

 

6B 

RST_PM

_A# 

 

First 

 

7A 

GA0 

Back-
plane 

First 

 

7B 

RST_PM

_B# 

 

First 

 

8A 

GA1 

Back-
plane 

First 

 

8B 

RST_PM

_C# 

 

First 

 

9A 

GA2 

Back-
plane 

First 

 

9B 

SMP 

 

First 

 

1C 

PS1_M1

 

First 

 

1D 

PS1_CU

1# 

 

First 

 

2C 

PS1_2# 

 

First 

 

2D 

PS1_1# 

 

First 

 

3C 

PS1_4# 

 

First 

 

3D 

PS1_3# 

 

First 

 

4C 

PS1_6# 

 

First 

 

4D 

PS1_5# 

 

First 

 

5C 

PS1_8# 

 

First 

 

5D 

PS1_7# 

 

First 

 

6C 

PS1_10

 

First 

 

6D 

PS1_9# 

 

First 

 

7C 

PS1_12

 

First 

 

7D 

PS1_11

 

First 

 

8C 

PS1_M2

 

First 

 

8D 

PS1_CU

2# 

 

First 

 

9C 

SCL_B 

 

First 

 

9D 

SDA_B 

 

First 

 

1E 

EN_M1

 

First 

 

1F 

EN_CU1

 

First 

 

2E 

EN_2# 

 

First 

 

2F 

EN_1# 

 

First 

 

3E 

EN_4# 

 

First 

 

3F 

EN_3# 

 

First 

 

4E 

EN_6# 

 

First 

 

4F 

EN_5# 

 

First 

 

5E 

EN_8# 

 

First 

 

5F 

EN_7# 

 

First 

 

6E 

EN_10# 

 

First 

 

6F 

EN_9# 

 

First 

 

7E 

EN_12# 

 

First 

 

7F 

EN_11# 

 

First 

 

8E 

EN_M2

 

First 

 

8F 

EN_CU2

 

First 

 

9E 

SCL_A 

 

First 

 

9F 

SDA_A 

 

First 

 

1G 

MP_M1 

 

First 

 

1H 

MP_CU

 

First 

 

2G 

MP_2 

 

First 

 

2H 

MP_1 

 

First 

 

3G 

MP_4 

 

First 

 

3H 

MP_3 

 

First 

 

4G 

MP_6 

 

First 

 

4H 

MP_5 

 

First 

 

5G 

MP_8 

 

First 

 

5H 

MP_7 

 

First 

 

6G 

MP_10 

 

First 

 

6H 

MP_9 

 

First 

 

7G 

MP_12 

 

First 

 

7H 

MP_11 

 

First 

 

8G 

MP_M2 

 

First 

 

8H 

MP_CU

 

First 

 

9G 

PWR_O

N_M2 

 

First 

 

9H 

PWR_O

N_M1 

 

First 

 

 

 

Summary of Contents for NATIVE-C1

Page 1: ...r Netzwerk und Automatisierungs Technologie mbH Konrad Zuse Platz 9 53227 Bonn Germany Phone 49 228 965 864 0 sales nateurope com www nateurope com NATIVE C1 1U 19 RACK MOUNTED MTCA CHASSIS DESIGNED...

Page 2: ...ne 13 4 1 1 TOPOLOGY 13 4 1 2 ELECTRICAL SPECIFICATIONS 13 4 2 Cooling Unit 26 4 2 1 FRONT PANEL AND LEDS 26 4 2 2 ELECTRICAL SPECIFICATIONS 27 4 3 Air Filter 31 4 4 Thermal Performance 33 5 SPECIFICA...

Page 3: ...NATIVE C1 TECHNICAL REFERENCE MANUAL V1 0 PREFACE 3 5 9 Compliance to REACH 42 5 10 Abbreviation List 42 6 DOCUMENT S HISTORY 43...

Page 4: ...ignment 19 Table 9 JSM Connector Pin Assignment 20 Table 10 Power Module Connector Pin Assignment 22 Table 11 Cooling Unit Connector Pin Assignment 25 Table 12 LED Functionality 26 Table 13 Power Supp...

Page 5: ...gure 5 Cooling Unit 26 Figure 6 Cooling Unit Front Panel 26 Figure 7 Air Filter 31 Figure 8 Airflow 32 Figure 9 Filter Performance 32 Figure 10 Slot Impedance 10 to 50 CFM 33 Figure 11 Single Mid Size...

Page 6: ...lost savings delays or interruptions in the flow of business activities including but not limited to special incidental consequential or other similar damages arising out of the use of or inability to...

Page 7: ...k Start Important information and mandatory requirements to be considered before operating the NATIVE C1 for the first time Chassis Design Detailed information on the overall design features and detai...

Page 8: ...offer users the flexibility to configure for a wide range of applications enterprise industrial control telecom wireless and others Its unique card guide design eases the insertion removal of AMCs The...

Page 9: ...and hot swappable Monitored fan power for early failure detection Air filter removed detection Optional Components Power Module NAT PM DC840 or NAT PM AC600 or any MTCA compliant power module Carrier...

Page 10: ...amaged and complete according to delivery note 3 2 Mechanical Requirements For operation the NATIVE C1 requires cooling units included and a power module separate order item Before installing or unins...

Page 11: ...position pulled out Push the module carefully into the dedicated connector until it is completely inserted The blue HS LED turns solid on With pushing the hot swap handle to lock position the HS LED s...

Page 12: ...Up to 6 AMCs full mid or compact sized 1 Power Module NAT PM DC840 NAT PM AC600 or any MTCA compliant PM 1 MCH NAT MCH or any MTCA compliant MCH 1 JSM JTAG Switch Module 2 redundant hot swappable man...

Page 13: ...5 AMC 6 Power Module 1 JSM Cooling Unit 1 Cooling Unit 2 Port 0 Fabric A Port 1 Fabric A Port 2 Port 3 Port 4 7 Fabric DEF G Port 8 11 Fabric DEF G Port 12 15 Port 17 20 TCLKA TCLKB TCLKC TCLKD FCLK I...

Page 14: ...nector Yamaichi CN080 170 0001 or equivalent Mating Connector Per MicroTCA R1 0 MCH Connectors 1 4 Yamaichi CN080 170 0001 or equivalent Mating Connector Per MicroTCA R1 0 JSM Connector Yamaichi CN080...

Page 15: ...NATIVE C1 TECHNICAL REFERENCE MANUAL V1 0 CHASSIS DESIGN 15 Table 4 AMC Connector Pin Assignment...

Page 16: ...NATIVE C1 TECHNICAL REFERENCE MANUAL V1 0 CHASSIS DESIGN 16 Table 5 MCH Tongue 1 Connector Pin Assignment...

Page 17: ...NATIVE C1 TECHNICAL REFERENCE MANUAL V1 0 CHASSIS DESIGN 17 Table 6 MCH Tongue 2 Connector Pin Assignment...

Page 18: ...NATIVE C1 TECHNICAL REFERENCE MANUAL V1 0 CHASSIS DESIGN 18 Table 7 MCH Tongue 3 Connector Pin Assignment...

Page 19: ...NATIVE C1 TECHNICAL REFERENCE MANUAL V1 0 CHASSIS DESIGN 19 Table 8 MCH Tongue 4 Connector Pin Assignment...

Page 20: ...dule First AMC 5 Payload Power P6 GND First Logic Ground P18 PP_6 Power Module First AMC 6 Payload Power P7 GND First Logic Ground P19 PP_7 Power Module First AMC 7 Payload Power P8 GND First Logic Gr...

Page 21: ...irst 6C PS1_10 First 6D PS1_9 First 7C PS1_12 First 7D PS1_11 First 8C PS1_M2 First 8D PS1_CU 2 First 9C SCL_B First 9D SDA_B First 1E EN_M1 First 1F EN_CU1 First 2E EN_2 First 2F EN_1 First 3E EN_4 F...

Page 22: ...st AMC 6 Payload Power P7 GND First Logic Ground P19 PP_7 Power Module First AMC 7 Payload Power P8 GND First Logic Ground P20 PP_8 Power Module First AMC 8 Payload Power P9 GND First Logic Ground P21...

Page 23: ...AMC 6 First AMC 6 Presence 4D PS1_5 AMC 5 First AMC 5 Presence 5C PS1_8 AMC 8 First AMC 8 Presence 5D PS1_7 AMC 7 First AMC 7 Presence 6C PS1_10 AMC 10 First AMC 10 Presence 6D PS1_9 AMC 9 First AMC 9...

Page 24: ...wer CU 1 2G MP_2 PM Agent First Mgmt Power AMC 2 2H MP_1 PM Agent First Mgmt Power AMC 1 3G MP_4 PM Agent First Mgmt Power AMC 4 3H MP_3 PM Agent First Mgmt Power AMC 3 4G MP_6 PM Agent First Mgmt Pow...

Page 25: ...JTAG Agent First Test Data In 11 TMS JTAG Agent First Test Mode Select 12 TRST JTAG Agent First Test Reset 13 TCK JTAG Agent First Test Clock 14 TDO JTAG Agent First Test Data Out 15 SCL_A IPMI Agent...

Page 26: ...ersion 1 0 Figure 5 Cooling Unit 4 2 1 Front Panel and LEDs The front panel of the NATIVE C1 Cooling Unit is equipped with four LEDs The functionality is described in the table below Figure 6 Cooling...

Page 27: ...Name Command Note Get Device ID 0x01 IPMI v1 5 Section 17 1 Get Self Test Results 0x04 IPMI v1 5 Section 17 4 Event Commands Network Function 0x04 0x05 Name Command Note Set Event Receiver 0x00 IPMI...

Page 28: ...3 0 R3 0 Table 3 86 Set Fan Level 0x15 PICMG 3 0 R3 0 Table 3 88 Get Fan Level 0x16 PICMG 3 0 R3 0 Table 3 87 HPMI 1 Commands Network Function 0x0C 0x0D Name Command Note Get Target Upgrade Capabilit...

Page 29: ...hreshold Assertion De Assertion Comparison Returned Settable Readable Upper Non Recoverable Yes Yes Readable Upper Critical Yes Yes Readable Upper Non Critical Yes Yes Readable Lower Non Critical No Y...

Page 30: ...dable Lower Non Critical Yes Yes Readable Lower Critical Yes Yes Readable Lower Non Recoverable Yes Yes Readable Fan Tachometer Sensors All readings have an accuracy of at least 5 Sensor Name Sensor N...

Page 31: ...Effective Area 7 5 sq in Initial Airflow Resistance 0 24 inches of water 68 CFM Airflow Resistance at Max Allowable Contamination 0 60 inches of water 68 CFM Allowable Filter Contamination 50 max Dus...

Page 32: ...NATIVE C1 TECHNICAL REFERENCE MANUAL V1 0 CHASSIS DESIGN 32 Figure 8 Airflow Figure 9 Filter Performance...

Page 33: ...33 4 4 Thermal Performance This chapter describes the NATIVE C1 s thermal performance Figure 10 Slot Impedance 10 to 50 CFM Note Impedance is higher in the I O Zone and Zone D because struts supportin...

Page 34: ...es of water The cross section drawing of the NATIVE C1 below shows 5 zones defined in the AMC spec plus a 6th zone BP Zone which exists in MicroTCA systems as there is room for air to flow between the...

Page 35: ...Zone D 9 22 7 97 8 44 9 12 9 54 Backplane Zone 3 24 3 43 3 56 3 47 3 49 This represents the potential airflow uniformity within the enclosure The airflow in all enclosures will shift depending on the...

Page 36: ...el Bay T Rise 0 C because of no power dissipation The figure below illustrates the temperature raise for power distribution shown in the table above in case of a single air mover failure Figure 15 Tem...

Page 37: ...NATIVE C1 TECHNICAL REFERENCE MANUAL V1 0 CHASSIS DESIGN 37 Figure 16 Typical Airflow Patterns...

Page 38: ...nics Parameter 1U Dimension 18 92 x 1 73 x 9 06 Weight 6 0 lbs The NATIVE C1 is compliant with the following standards EIA 310D Cabinets Racks Panels and Associated Equipment DIN 41494 P1 Panel Mounti...

Page 39: ...C to 5 C Any valid condition Normal Operation 5 C to 45 C 100 Short Term Operation 45 C to 55 C Linear derating to 80 at 55 C Table 22 Other Environment Criteria Specification Reference Relative Humi...

Page 40: ...t ETS300 019 1 2 Part 1 2 Class 2 3 equipment ETS300 019 1 3 Part 1 3 Class 3 2 equipment PICMG AMC 0 R2 0 PICMG AMC 2 R1 0 PICMG AMC 1 R2 0 PICMG MTCA 0 R1 0 5 6 Compliance to RoHS Directive Accordin...

Page 41: ...allows a greater flexibility in business to business relation ships This pays tribute to the fact with industrial use electrical and electronical products are commonly integrated into larger and more...

Page 42: ...rmation remains in effect or will be otherwise stated immediately to our customers 5 10 Abbreviation List Table 24 Abbreviation List Abbreviation Description AMC Advanced Mezzanine Card CFM Cubic Feet...

Page 43: ...NATIVE C1 TECHNICAL REFERENCE MANUAL V1 0 DOCUMENT S HISTORY 43 6 DOCUMENT S HISTORY Table 25 Document s History Rev Date Description Author 1 0 18 08 2021 initial release na...

Reviews: