NATIVE-C1
T
ECHNICAL
R
EFERENCE
M
ANUAL
V1.0
C
HASSIS
D
ESIGN
- 29 -
Table 15
–
Mandatory Sensors
Event and Status Sensors
These sensors are implemented according to the requirements and specifications of
the relevant standards
Sensor Name
Sensor Number
Hot-Swap
0x70
Filter PS
0x71
Temperature Sensors
All readings have an accuracy of at least 5% and an offset of -40 °C
Sensor Name
Sensor Number
Resolution
Applicable Models
CPU Temp
0x01
1°C / bit
All
Threshold
Assertion/
De-Assertion
Comparison
Returned
Settable / Readable
Upper Non-Recoverable
Yes
Yes
Readable
Upper Critical
Yes
Yes
Readable
Upper Non-Critical
Yes
Yes
Readable
Lower Non-Critical
No
Yes
Readable
Lower Critical
Yes
Yes
Readable
Lower Non-Recoverable
Yes
Yes
Readable
Sensor Name
Sensor Number
Resolution
Applicable Models
Airflow Temp
0x02
1°C / bit
All
Threshold
Assertion/
De-Assertion
Comparison
Returned
Settable / Readable
Upper Non-Recoverable
No
No
None
Upper Critical
Yes
Yes
Readable
Upper Non-Critical
Yes
Yes
Readable
Lower Non-Critical
Yes
Yes
Readable
Lower Critical
Yes
Yes
Readable
Lower Non-Recoverable
No
No
None