POWER INSTALLATION INSTRUCTIONS
CONTINUED
HOT TUB ANATOMY
Whirlpool Jet
Suction Fittings
Air Controls
Air Controls
Air Controls
Air Controls
Cup Holder
Ozone Jet
Cup Holders
Cup Holders
Filter
Waterfall Jet
Light
Access Panel
(side of cabinet)
Topside Control
12
| NORDIC HOT TUBS | OWNER’S MANUAL
WARNING: DO NOT TURN ON POWER UNTIL TUB IS FILLED COMPLETELY WITH WATER!
120 VOLT CORD CONNECTION OPTION
(110-all-in, Classic and Modern Series)
The cord connection option is only available for 120V operation on the models rated 12/15 A. Only the manufacturer
recommended power cord and GFCI should be used for cord connected installations. Only plug the cord into a dedicated
120V/15 amp receptacle after following the steps below.
Electrical installation should be performed by a qualified, licensed electrician.
Warning: Make sure that cord is unplugged from the wall socket prior to proceeding with the following steps.
1. Remove cabinet service panel. The panel is secured with Phillips Head truss machine screws.
2. Remove system controller cover.
3. If spa was manufactured with a cord, disconnect cord wires from
terminal TB1 and ground wire from ground bar.
4. Loosen cord strain relief.
5. Remove cord.
6. Remove strain relief.
7. Drill hole for conduit through bottom or side of spa.
8. Secure conduit at system controller box.
9. Connect hot and neutral wires to corresponding terminals TB1.
Connect ground wire to grounding bar on the outside of box by
running it though hole marked for ground wire. Double check that all
electrical connections are tight.
10. Reinstall system cover and hot tub access panel.
Summary of Contents for Nordic Hot Tubs IMPULSE