(Revised 2011-09-02)
13
TYPICAL APPLICATION
CONNECTING THE UNIT
For 10Base-T ports, plug a Category 3 (or greater) twisted pair cable into the RJ45 connector. For
100Base-T ports, plug a Category 5 (or greater) twisted pair cable into the RJ45 connector. Connect the
other end to the far end station. The total length of cable should not exceed 100 meters. Although power is
being applied to the Ethernet port, the power does not boost data on the lines.
TROUBLESHOOTING
1.
Make sure the (Power LED) is ON.
2.
Make sure you are supplying sufficient current for the 100-POE4 and all the powered devices plugged
into it.
Note: The inrush current and steady state current is dependent on the power requirements
of the powered devices plugged into the 100-POE4
.
3.
Verify that the POE light is on solid for the port in question.
4.
Verify cabling used between stations. (The 100-POE4 is a mid-span PSE, not a POE switch).
5.
Verify that cabling is Category 3 or greater for 10Mbit Operation.