608MFX NETWORK CONFIGURATION
The N-TRON 608MFX is a product derivative of the OSM/ESM family jointly
manufactured by Siemens and N-TRON. Some of the software menus may refer to
the OSMTP62 (Optical Systems Module) or ESM (Electrical Systems Module) when
identifying the N-TRON 608MFX. These names are synonymous.
There are 3 main ways to configure and/or monitor the N-TRON 608MFX:
1.
Command Line Interpreter - Serial Port
2.
Command Line Interpreter - TELNET
3.
SNMP (SNMP Host SW not supplied by N-TRON).
COMMAND LINE INTERPRETER (CLI)
You can configure and/or query all the important parameters of a 608MFX using a
command line interpreter. These functions may be accessed using the serial port
(marked V24) or via TELNET.
The CLI can be used for the following:
•
To set the IP address and the subnet mask of the 608MFX.
•
To assign new passwords for the 608MFX.
•
To view/modify parameters of the 608MFX.
To access the CLI, connect a PC serial port to the 608MFX serial port (see HW
Installation guide). After a successful connection and reboot, the boot menu should
be displayed:
Password Protection
Access using the CLI is password–protected. You can log in as administrator or as
user (with different passwords). An administrator can read and modify 608MFX
parameters. a user can only read 608MFX settings. Note: The default admin
password is
admin
, and the default user password is
user
.
Once the connection has been established via the serial port or TELNET, the
following prompt appears:
Login:
Type in
admin
(for administrator) or
user
(for user) according to your access
permission and then press
[Return]
.
Password: