(Revised 2012-05-01
Page 10 of 170
WARNING: Do not work on equipment or cables during periods of lightning activity.
WARNING: Do not perform any services on the unit unless qualified to do so.
WARNING: Do not block the air vents.
WARNING: Observe proper DC Voltage polarity when installing power input cables. Reversing voltage
polarity can cause permanent damage to the unit and void the warranty.
Hazardous Location Installation Requirements
1.
This equipment is suitable for use in Class I, Div. 2, Groups A, B, C, D or non-hazardous locations
only.
2.
WARNING: Explosion Hazard – Substitution of components may impair suitability for Div. 2.
3.
WARNING: Explosion Hazard - do not disconnect while circuit is live, unless area is known to be
non-hazardous.
4.
WARNING: Explosion Hazard – do not replace the device unless power has been switched off or
the area is known to be non-hazardous.
5.
Use 90°C or higher rated Copper wire, (0.22Nm) 2lb/in Tightening torque for field installed
conductors.
Please make sure the 710FX2 Series Ethernet Switch package contains the following items:
1.
710FX2 Series Switch
2.
Product CD
Contact your carrier if any items are damaged.
Installation
Read the following warning before beginning the installation:
WARNING
Never install or work on electrical equipment or cabling during periods of lightning activity. Never connect
or disconnect power when hazardous gasses are present.
Disconnect the power cable before removing any enclosure panel.
UNPACKING
Remove all the equipment from the packaging, and store the packaging in a safe place. File any damage
claims with the carrier.
Summary of Contents for 710FX2 Series
Page 1: ...710FX2 Managed Industrial Ethernet Switch User Manual Installation Guide ...
Page 11: ... Revised 2012 05 01 Page 11 of 170 CLEANING Clean only with a damp cloth ...
Page 33: ... Revised 2012 05 01 Page 33 of 170 Administration SNMP Continued ...
Page 37: ... Revised 2012 05 01 Page 37 of 170 DHCP Server Setup Profiles Continued ...
Page 46: ... Revised 2012 05 01 Page 46 of 170 DHCP Relay Local IP Setup Continued ...
Page 52: ... Revised 2012 05 01 Page 52 of 170 Ports Configuration Continued ...
Page 83: ... Revised 2012 05 01 Page 83 of 170 The user can specify the manual router ports ...
Page 86: ... Revised 2012 05 01 Page 86 of 170 IGMP RFilter Continued Modifying rfilter port settings ...
Page 94: ... Revised 2012 05 01 Page 94 of 170 N Ring Advanced Configuration Continued ...
Page 119: ... Revised 2012 05 01 Page 119 of 170 If a Configuration Device is present that is presented ...