CIP – Status
The Status tab under the CIP category will display the CIP status.
The following switch status and partner status information will be shown:
Identity Information:
Product Name: Switch Model Number.
Vendor: This is N-Tron's ODVA EtherNet/IP Vendor ID (1006).
Device Type: The ODVA Device Type is Communications Adapter (= 0x0C hex).
Major Revision: The Major Revision of the CIP implementation.
Minor Revision: The Minor Revision of the CIP implementation.
Serial Number (hex): CIP Serial number, unique across all N-Tron CIP devices. This is the
last 4 octets of the base switch MAC.
Connection Information:
Number of Multicast
Connections:
Current number of CIP Ethernet/IP class 1 (multicast) connections.
Number of Unicast
Connections:
Current number of CIP Ethernet/IP class 3 (unicast) connections.
Summary of Contents for 710FX2 Series
Page 1: ...710FX2 Managed Industrial Ethernet Switch User Manual Installation Guide ...
Page 11: ... Revised 2012 05 01 Page 11 of 170 CLEANING Clean only with a damp cloth ...
Page 33: ... Revised 2012 05 01 Page 33 of 170 Administration SNMP Continued ...
Page 37: ... Revised 2012 05 01 Page 37 of 170 DHCP Server Setup Profiles Continued ...
Page 46: ... Revised 2012 05 01 Page 46 of 170 DHCP Relay Local IP Setup Continued ...
Page 52: ... Revised 2012 05 01 Page 52 of 170 Ports Configuration Continued ...
Page 83: ... Revised 2012 05 01 Page 83 of 170 The user can specify the manual router ports ...
Page 86: ... Revised 2012 05 01 Page 86 of 170 IGMP RFilter Continued Modifying rfilter port settings ...
Page 94: ... Revised 2012 05 01 Page 94 of 170 N Ring Advanced Configuration Continued ...
Page 119: ... Revised 2012 05 01 Page 119 of 170 If a Configuration Device is present that is presented ...