(Revised 2012-05-01)
Page 34 of 163
Administration – Fault
The Fault tab under the Administration category provides configurable selections indicating the way to
notify when a Power, N-Ring Manager, N-Link fault, or Port Usage Fault occurs. The notification may
consist of any combination of the options: Show Web, Show LED, and Contact. Power signal faults consist
of V
1
and V
2
. N-Ring Manager signal faults consist of: Broken, Partial Break (Low), Partial Break (High),
and Multiple Managers. N-Link Faults are reported by the N-Link Master and by the N-Link Slave. Port
Usage Fault, if enabled, triggers when actual usage is below the Usage Alarm Low setting, or above the
Usage Alarm High setting (see Port Configuration View and Port Utilization View).
Note: V
1
and V
2
Power Faults are disabled in factory defaults.
Summary of Contents for 712FX4 Series
Page 1: ...712FX4 Managed Industrial Ethernet Switch User Manual Installation Guide...
Page 11: ...Revised 2012 05 01 Page 11 of 163 CLEANING Clean only with a damp cloth...
Page 33: ...Revised 2012 05 01 Page 33 of 163 Administration SNMP Continued...
Page 37: ...Revised 2012 05 01 Page 37 of 163 DHCP Server Setup Profiles Continued...
Page 40: ...Revised 2012 05 01 Page 40 of 163 DHCP Server Setup IP Maps Continued...
Page 46: ...Revised 2012 05 01 Page 46 of 163 DHCP Relay Local IP Setup Continued...
Page 52: ...Revised 2012 05 01 Page 52 of 163 Ports Configuration Continued...
Page 82: ...Revised 2012 05 01 Page 82 of 163 IGMP RFilter Continued Modifying rfilter port settings...
Page 90: ...Revised 2012 05 01 Page 90 of 163 N Ring Advanced Configuration Continued...
Page 113: ...Revised 2012 05 01 Page 113 of 163 If a Configuration Device is present that is presented...
Page 149: ...Revised 2012 05 01 Page 149 of 163...