CONNECTING THE UNIT 
 
For 902 & 904 FX & FXE units, remove the dust cap from the fiber optic connectors and connect the 
fiber optic cables.  The TX port on the 902 and/or 904 units should be connected to the RX port of the 
far end station.  The RX port on the 902 and/or 904 units should be connected to the TX port of the far 
end station. 
 
For 10/100 Base-TX ports, plug a Category 5 twisted pair cable into the RJ45 connector.  Connect the 
other  end  to  the  far  end  station.    Verify  that  the  LNK  LED’s  are  ON  once  the  connection  has  been 
completed.    For  Switch  to  Switch  or  Switch  to  Repeater  connections,  since  the  908TX  supports  the 
advanced  MDIX  function,  there  is  no  need  to  use  crossover  cables.    The  908TX  will  sense  &  adapt 
accordingly. 

 

TROUBLESHOOTING 

1.

 

Make sure the   (Power LED) is ON. 

2.

 

Make sure the ! (Error LED) remains OFF 3 seconds after initial power up. 

3.

 

Verify that Link LED’s are ON for connected ports. 

4.

 

Verify straight through cabling used between stations.   

5.

 

Verify cabling (pin-outs & integrity). 

6.

 

Verify that cabling is Category 5 (or higher) for 100Mbit Operation. 

7.

 

Verify TX is connected to far end RX and vise versa    (902 and 904 FX/FXE only). 

 
SUPPORT 
 

Contact N-TRON Corp. at: 
TEL: 251-342-2164 
FAX: 251-342-6353 
Website: www.n-tron.com 
E-Mail: support@n-tron.com  
 
 

FCC STATEMENT 
 
This product complies with Part 15 of the FCC-A Rules. 
Operation is subject to the following conditions: 
(1)

 

This device may not cause harmful Interference 

(2)

 

This device must accept any interference received, including interference that may cause undesired 
operation. 

 

Summary of Contents for 900

Page 1: ...900 Series Industrial Ethernet Switch Installation User s Guide...

Page 2: ...900B 900N 3 Slot Enclosure and Backplane 900B FP Filler Panel for empty slots 908TX Module 902FX SC Module 902FX ST Module 902FXE SC YY Module 902FXE ST YY Module 904FX SC Module 904FX ST Module 904F...

Page 3: ...limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N TRON Corp be liable for any incidental special indirect or consequential damages whatsoever...

Page 4: ...es during periods of lightning activity WARNING Do not perform any services on the unit unless qualified to do so WARNING Do not block the air vents WARNING Observe proper DC Voltage polarity when ins...

Page 5: ...with Local National Codes of Authorities Having Jurisdiction 4 Power must be supplied by an isolating source and a 3 3A max rated UL recognized fuse must be installed immediately before the unit 5 Cla...

Page 6: ...o supports MDIX auto sensing for auto connector of straight through or crossover cables and provides 8 Category 5 compliant 10 100 BaseT connections for high performance network design and hub repeate...

Page 7: ...n WARNING The 902FXE and 904FXE unit contain a class 1 laser Do not stare into the laser beam fiber optic connector when installing or operating the product Never install or work on electrical equipme...

Page 8: ...If Half Duplex operation is desired then follow these steps using proper wrist strap grounding techniques 1 Remove the power power plugs from the unit 2 Loosen all thumbscrews remove all modules 3 Rem...

Page 9: ...o place To remove the unit from the 35 mm industrial DIN Rails Apply downward force to the unit until it disengages from the bottom of the unit from the DIN Rail Then rotate the unit approximately 15...

Page 10: ...orted Two Slot Configuration When installing two 902FX 904FX and or 908TX modules in the top two slots of the 900B chassis Configure both modules as follows JP1 pins 1 2 shorted JP2 pins 3 4 shorted T...

Page 11: ...he table below describes the operating modes LED Color Description GREEN Power is Applied OFF Power is OFF LNK GREEN Link between ports established OFF No Link between ports ACT GREEN Data is active b...

Page 12: ...remain off during reset This is normal behavior LED s The table below describes the operating modes LED Color Description GREEN Power is Applied OFF Power is OFF LNK GREEN Link between ports establis...

Page 13: ...the Voltage Input Plug s back into the side header All 10 100BaseT LED s will flash ON Momentarily For fiber optic ports only port 1 will flash momentarily 5 Verify the Power LED stays ON GREEN Note O...

Page 14: ...EM nuts on the enclosure When using an unused PEM nut to connect a ground lug via a machine screw care should be taken to limit the penetration of the outer skin by less than 1 4 in Failure to do so m...

Page 15: ...ed to use crossover cables The 908TX will sense adapt accordingly TROUBLESHOOTING 1 Make sure the Power LED is ON 2 Make sure the Error LED remains OFF 3 seconds after initial power up 3 Verify that L...

Page 16: ...e 20o C to 85o C 0 F to 185o F Operating Humidity 10 to 90 Non Condensing Operating Altitude 0 to 10 000 ft Shock and Vibration Bulkhead Mounting Shock 200g 10ms Vibration 1g 10 500Hz 3 axis Seismic 2...

Page 17: ...ck Mount Kit 900 PM Panel Mount Kit 908TX Eight ports 10 100BaseTX RJ45 902FX XX Two ports 100BaseFX multimode fiber 902FXE XX YY Two ports 100BaseFX singlemode fiber 904FX XX Four ports 100BaseFX mul...

Page 18: ...ES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OP...

Reviews: