background image

KK-10100_150409_EN_00

10100

SWITCH TYPE MOTION SENSOR

Detection range is determined at the temperature of 20 °C.

(e) Time Setting

Light ON time can be adjusted continuously from
“10 sec 

±

 1 sec. / 5 min 

±

 10 sec.” If you turn the knob

clockwise device will operate at minimum time.(10 second)

Control dial set min  = Shortest time (10 sec. 

±

 1 sec.)

Control dial set max = Longest time (5 min. 

±

 10 sec.)

(f) Daylight Setting

The sensor’s response threshold can be infinitely varied from 2-2000 lux.
If you turn the knob clockwise device will operate at dark.

Control dial set      = Daylight operation approx. 2000 lux.
Control dial set      = Night-time operation approx.2 lux.

(d) Switch Setting

Auto = In this mount device will work as a motion sensör.
Off    = Lamb will be always off.
On    = Lamb will be always on.

NOTE : Device will automatically make its own offset by checking environment for
approximately 5 minutes after the first installation. After this period device will operate
normally. If you think the device does not operate normal in first installation, please wait for
5 minutes and start to test again. Be sure that there is no motion by this period.

MOUNTING

Use this aparate (surface mount aparate) when making
surface mount
Fix the aparate on the wall shown by (a)
Pass the cables through the hole shown by (b)

DETECTION AREA

Detection area of motion sensors depends on the angle between PIR detector and moving
direction, temperature, mounting style and mounting places.
Temperature is very important for operation of motion sensors like all electronic devices.
Using
higher value of loads written on manuals and packages will decrease temperature inside the
device when using Na-De Motion Sensor. As a result detection range will decrease and may
cause defect of electronic components. Environment temperature will also cause decrease
of detection range. Detection range given is determined at 20 °C .If the weather is hot, it will
decrease.

Walking tangential to the sensor

(normal detection range)

Figure 1

The maximum detection range can be realized when walking tangential to the sensor
(Figure 1). When walking directly to the sensor detection range will be low. Because you
will not be able to cut vertical areas. Detection range of 10100 products 9 meters as
diameter 4,5 meters as radius.

GUARANTY

We will remedy defects caused by material flaws or manufacturing faults. The warranty will
be met by repair or replacement at our own discretion. The warranty shall not cover damage
to wear parts, damage or defects caused by improper treatment or maintenance. Further
consequential damage to other object is excluded.
Claims under the warranty will only be accepted if the unit is sent fully assembled and well
packed complete with a brief description of the fault, a receipt or invoice ( date of purchase
and dealer’s stamp) to the appropriate Service Center.

Walking directly to the sensor

(lover detection range)

SETTING

(d)

(e)

(f)

TROUBLESHOOTING

MALFUNCTION

CAUSE

SOLUTION

• Lamp is off

• There is no
electricity on the
device

• Continuously
lamp is on

• Change perception
area in device

• Daylight adjustment set to
night-time mode during daytime
operate
• Bulb faulty or there is no
connection
• Power switch off or no electricity

• Fuse faulty

• Switch is at OFF position

• Fuse switch off or fuse faulty

• Connection faulty.

• Continuously movement in
detection zone
• Cars on the streets are being
detected.
• Wind, rain, snow is moving to the
trees & bushes or open windows in
detection zone.
• Switch is at ON position

• Sudden temperature changes due
to weather(wind, rain, snow) or the
air expelled from fans.
• Different ambient temperatures.

• Control daylight setting and
re-adjust
• Fit the bulp into the lamp holder,
if it still does not operate, change
the bulb.
• Check the electricity and power
on.
• Change the fuse.

• Select Auto position of switch.

• Check the fuse if necessary use
a new fuse.
• Check the connection cables.

• Check the detection zone.

• Avert it is being detection.

• Change detection zone, change
site of installation.

• Select Auto position of switch.

• Change site of installation or
keep the reasons away.

• Change site of installation.

USAGE AREAS

• At the switch cases
• At the building entrances, stair vestibutes.
• At the long halls within the flats.
• At the places required within the flats.
• At the parking garage.
• At the requisite locations within the hotels.
• At the schools, hospitals and oil filing station.

“OFFERS ENERGY SAVING FEATURE”

GENERAL SECURITY CAUTIONS

• Take off the original package and control if there is any damage of transportation and
general view of the product.
• Do not use the product at cross purposes.
• Keep it away from water and moist areas.
• Do not use the product at dusty, dirty and rusty places.
• Do not supply high voltage.
• Do not apply any liquid.
• Protect from any stroke.
• Using 230-240V~ voltage is so dangerous that only the specialist
electricians must install and apply.

CAUTIONS FOR INSTALLATION AND USAGE

• Installing must be carried out professionally in accordance with applicable national wiring
and electrical operating conditions.
• Turn off the network before mounting.
• Do not mount the product near the radiator and moist areas.
• Place the product horizontal to the wall/ceiling.
• Fix the bulbs before operating.
• Use 10A fuse the supply input.
• Factory setting; daylight adjustment is at darkness, time adjustment is at the shortest.
• Setting can be made 10 - 15 second after the releasing of the power.
• Time and daylight setting can be made during the day or night.
• Do not change the time and daylight settings abruptly.
• Do not make a second adjustment before you get a result from the first setting
of the time and daylight.
• After you determine the right setting of the daylight, you can arrange the time as you need.
• The best result for the daylight setting can be obtained by adjusting the minimum. And that
you can find the correct setting for sensitivity incrementally.
• When a cleaning needed for the product, take of carefully and clean with a dry rag.
• Avoid mounting the detector close to objects that can cause rapid temperature changes
such as heaters, fans, refrigerators and ovents etc, and prevent the detector from point-
blank sunshine.
* It can cause the device operate inaccurately if there is tree, brushes etc. in the
coverage area.

(a)

(a)

(b)

(d)

(c)

(c)

(e)

(f)

Connect the line cable to the terminal shown by L
Connect the neutral cable to the terminal shown by N
You can also connect the neutral cable of lamb from here
Connect line out cable(for the lamp) to the terminal shown
by LS

Fix the product to the surface mount aparate shown by (c)
when making surface mounting
Fix the product on the wall shown by (c) when making flush
mount
You can select On, Off or Auto mode with the switch shown
by (d)

L N LS

DETECTION AREA

Wall

1-2 m (From base)

8 m

4 m

2.8 m.

Ceiling

9 m.

4,5 m.

4,5 m.

www.na-de.com.tr   •   info@na-de.com.tr

‹stanbul Deri Organize Sanayi Bölgesi Tufle Sok. No:8

M1-8 Özel Parsel 34953 Tuzla / ‹STANBUL - TÜRK‹YE

GB

HU-000650

TÜV

Rheinland

R

TS EN

60669-2-1

Complies with ROHS Regulation Directive

2002/95/EC

SPECIFICATIONS

10100

Operating Voltage

Detection angle

Mounting Height

Detection Range

Time Setting

Lighting Load

Protection Class

Operating Temperature

Power consumption

230-240 V~   50/60 Hz

360° at the Ceiling

180° on the Wall

2.8 m. at the ceiling

1-2 m. on the wall

9 m. at the ceiling / 8m. on the wall

10 sec. 

±

 1sec. / 5 min. 

± 

10 sec.

Max 1000W Incandescent

Max 400W Fluorescent

IP20

CLASS 2

-20 °C ~ +40 °C

1.5W

Summary of Contents for 10100

Page 1: ...2000 lux aras nda ayarlanabilir Ayar saat y n nde evirdi inizde r n yaln zca gece al acakt r konumunda Hem gece hem g nd z al r konumunda Yaln z gece al r d Switch Ayar Auto Bu konumda r n sens r poz...

Page 2: ...trol daylight setting and re adjust Fit the bulp into the lamp holder if it still does not operate change the bulb Check the electricity and power on Change the fuse Select Auto position of switch Che...

Page 3: ...No 8 M1 8 zel Parsel 34953 Tuzla STANBUL T RK YE Camminata orizzontale al sensore Camminata verticale al sensore Figura 1 La distanza di percezione stata regolata secondo le condizioni di un ambiente...

Page 4: ...ensiune Lampa este aprinsa in continuu Modificare a ariei de detectie Lampa este setata in modul de noapte in timpul operarii pe timp de zi Becul este defect Lipsa alimentarii cu tensiune Siguranta es...

Page 5: ...lang Ingeval in de door Na De bewegingsensoren gestuurde armaturen lampen worden aangebracht met een hoger vermogen dan op het etiket van het product de verpakking en de gebruikshandleiding is aangege...

Page 6: ...pas changer les r glages tout d un coup Ne pas commencer au r glage suivant avant de voir le r sultat du pr c dent Vous pouvez faire le r glage du temps apr s avoir d termin la position du r glage de...

Page 7: ...on LS DISTANCIA DE PERCEPCI N La distancia de percepci n de los sensores de movimiento depende del lugar y la forma de montaje la temperatura y el ngulo entre el dedector y la direcci n del movimiento...

Page 8: ...d c c e f L N LS 9 m 2 8 m 8 m 4 m 4 5 m 4 5 m www na de com tr info na de com tr stanbul Deri Organize Sanayi B lgesi Tu e Sok No 8 M1 8 zel Parsel 34953 Tuzla STANBUL T RK YE RUS 10100 HU 000650 T...