Rev. 11-26-14
Part #15-9324
www.NabcoEntrances.com
1400 Fold Door System
Install Frame
3-10
Sec on
3c:
Secure Header to Jamb Tubes
1. Remove (4) 1/4-20 x 3/4 inch bolts and (4) 1/4 inch star washers that were pre-screwed
inside rivnuts located on each Jamb tube.
a. Save hardware for reinstallation.
2. Position Jamb tubes on either side of Header so the Weathering faces up, towards the Exterior
side of building (opposite of Magnetic Latches). Please see Figure 3-4.
3. Orientate the Frame so the open end at the bottom of each Jamb Tube is facing the Exterior
side of the building.
Figure
3-4
Orientate Frame to Exterior Side of Building
DN 0830
Magne c Latches
Bo om of Jamb Tube
(towards Exterior opening)
EXTERIOR
Door Opening
Weathering must face up
(towards Exterior opening)
4. Use a 7/16 inch Socket on a 6 inch extension to secure the Header to each Jamb Tube with (4)
1/4-20 x 3/4 inch bolts and (4) star washers that were saved. Please see Figure 3-5.
a. Do not overtighten Bolts.
Figure
3-5
Secure Header to Jamb Tubes
DN 0327
1/4-20 x 1” Bolt
1/4 “ Star Washer
Jamb Tube
Header
Sec on
3d:
Anchor Placement
Anchors are not provided by NABCO.
Anchors must be appropriate for the type of structure being fastened to.
Ensure anchor heads to not come in contact with edges of glass to prevent breakage.
Note:
It is recommended to countersink holes as required to lush the surface.
Note:
It is recommended to drill tap threads for 1/4 inch anchors in a steel or aluminum structure.
Note:
If anchor points in structure are known, the aluminum door framing can be predrilled prior to