11 of 26
www.NabcoEntrances.com
GT 710-8710 OPUS Low Energy Swing Doors Quick Set-Up and Parts Guide
Rev 12-20-17
P/N C-00178
4. The distance between the Center Eye of the Link and the end of Rod equals: Minus (1) inch from the appropriate Rod length
that was found within Table 2 or Table 3.
5. Go to the Link that is connected to the Arm Shoe.
6. Measure from the Center Eye down to the end of Rod - according to the adjusted measurement. Mark that spot.
a. For example: 14 inches minus (1) inch = 13 inches = adjusted measurement.
7. Cut the Rod.
Full Rod Length
Rod Length - minus 1”
DN 1739
Center Eye
of Link
Cut Mark
Figure 13
Measure Rod Length
SECTION 5 .3: Secure the Arm Shoe to the Door
1. Go to the back of the Swing door. Insert (1) Sex Bolt into each drilled hole.
2. Go to the front of the Swing door. Secure the Arm Shoe to the Swing Door with (2) 1/4-20 x 2-1/4” Screws.
DN 1931
Arm Shoe
Sex Bolt
1/4-20 x 2-1/4”
Phillips Head Screw
Figure 14
Secure Arm Shoe to the Swing Door
3. Thread the Nut and Link back onto the Rod. Loosely tighten the Nut.
4. Measure the distance between the Nut and the Arm Shoe. Mark that measurement down.
5. Remove the Link and Nut.
6. Obtain (1) color coordinated Plastic Tube from the Outswing Rod assembly.
7. Cut the Plastic Tube to the same measured length as the Rod.
8. Slide the Plastic Tube over the Threaded Rod.
9. Thread the Nut and Link back onto the Rod. Tighten the Nut.
DN 1097
Threaded Rod
Color Coordinated Sleeve
Figure 15
Secure Arm Shoe to the Swing Door