Rev. 9-24-14
Part #15-10683
GT 710-8710 Swing Door System Low Energy Operator
Install the Magnets
7-21
CHAPTER 7: INSTALL THE MAGNETS
Power must be turned OFF while installing the Magnets.
Note: Magnetic Reed Switches are reversed according to Handing of door (LH vs RH).
When Magnets are correctly set, the Green LED on the Magnum 4A Control will be:
X
OFF when the door is closed.
X
Fast Flashing when opening.
X
On Solid at Back Check.
X
Slow flashing when closing.
X
OFF again at Latch Check
Figure 7-1
Insert Magnet underneath Door Closed Switch
DN 0586
Back Check Magnet
Door Closed Magnet
Main Sprocket Gear
4 3
2
1
BACK
CHECK
SWITCH
DOOR
CLOSED
SWITCH
FOR
XXX HAND
UNITS
1.►
Go to the Magnum 4A Control. Disconnect Power.
2.►
Unplug the J4 Connector.
3.►
Set the Current Limit Switch to Maximum. (Clockwise)
Section 7a: Insert the Back Check Magnet
1.►
Obtain (1) 1/4 inch square x 1 inch long Magnet. Please see
.
2.►
Manually open the Swing door to the Fully Open position (90 degrees).
3.►
Place the Magnet (White side up) directly underneath the Back Check Magnetic Switch.
CAUTION