background image

ElectricalInstallationManualU-30“D”Control

www.NabcoEntrances.com

Part #C-00121 

Rev. 8-25-16

iv 

GENERAL SAFETY RECOMMENDATIONS

Do not install, operate or service this product unless you have read and understand 

the General Safety Recommendations, Warning Labels, contained in this manual. 

Failure to do so may result in bodily injury, or property damage.

Read, study and understand the installation and operating instructions contained in, 

or referenced in this manual before operating. If you do not understand the instruction, 

ask a qualified technician. Failure to do so may result in 

bodily injury, or property 

damage and will nullify all warranties.

Disconnect all power to the junction box prior to making any electrical connections. 

Failure to do so may result in seriouc personal or fatal injury. When uncertain whether 

power supply is disconnected, always verify using a voltmeter.

Do not place finger or uninsulated tools inside the electrical controller. Touching wires 

or other parts inside the enclosure may cause electrical shock, serious injury or death. 

The Ground wire from the Magnum IV Control 120 VAC Harness, and the Incoming 120 

VAC Ground wire must be connected to the Ground screw located within the Swing 

door Header.

If the door appears broken or does not seem to work correctly, it should be 

immediately removed from service until repairs can be carried out or a qualified 

service technician is contacted for corrective action.

Notice:    This manual, the owner’s manual and all other associated manuals must be given to and 

retained by the purchasing facility or end user.

Notice:    Wiring must meet all local, state, federal or other governing agency codes.

Notice:    All electrical troublshooting or service must be performed by qualified 

 

electrical technicians and must comply with all applicable governing  

agency codes.

Note:       All Adjustments must be made with a small screwdriver. Do Not use a pencil.
Note:       Do Not take shortcuts.

WARNING

WARNING

WARNING

DANGER

DANGER

CAUTION

CAUTION

Summary of Contents for GYRO TECH GT-1175

Page 1: ...LOCK ASSY P N 22 10522 03 FAIL SECURE VIO GRY WHT BLK 1 6 110V 20VAC 50 60Hz Microprocessor Controller 248901 GYRO TECH HOLD OPEN NIGHT ONE WAY TWO WAY MODE M1 M0 Open Gnd Open Open Open Gnd Gnd Gnd...

Page 2: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 3: ...Y OPERATING WIRES 4 10 Section 4a 16 Pin Controller Terminal Block Assignments 4 10 Section 4b Sensor Wire Connections 4 11 Section 4c Rocker Switch Settings 4 12 CHAPTER 5 WIRING DIAGRAMS 5 14 Sectio...

Page 4: ...h Fail Safe Electric Lock 7 24 Section 7c U30 with Fail Secure Electric Lock 7 25 Section 7d U30 with Magnetic Lock 7 26 CHAPTER 8 CUSTOM WIRING 8 27 Section 8a U30 Configured for Remote Control of Mo...

Page 5: ...uld not be considered for property damage unless personal injury risk is present Indicates a hazardous situation which has some probability of severe injury It should not be considered for property da...

Page 6: ...e finger or uninsulated tools inside the electrical controller Touching wires or other parts inside the enclosure may cause electrical shock serious injury or death The Ground wire from the Magnum IV...

Page 7: ...alfunction All installation changes and adjustments must be made by qualified NABCO trained technicians Section 1b Objective The U30 Microprocessor Controller is designed to be installed within the He...

Page 8: ...ed power supply Section 2b Electrical Specifications All Wiring Diagrams included within this manual reflect typical primary and secondary circuits that are installed at the NABCO Factory The low volt...

Page 9: ...160 mA Total 420 mA 420mA exceeds 350mA An Auxiliary Power Supply must be used to supply power to the Optex Beam Module Section 2d Header Layout Nabco GT 1175 Sliding Door systems come in many sizes a...

Page 10: ...tector Sidelite Presence Sensor Exterior Activation BA 62 SLS M1 H M0 Holding Beam Interior Activation 12VDC Common 12VDC 6B 9DC12V 7 61 Mode Switch see Mode SW Usage shown left HANDY TERMINAL 6P RELA...

Page 11: ...GT 1175 Slide Door Failure to do so may result in damage to the Slide door and or injury to the installer and will nullify all warranties Figure 3 1 Connect Incoming 120 VAC Wires to Power Supply AC 1...

Page 12: ...ription 1 9DC12V Brown X X Output terminal Sensor power source Output is 12VDC with a maximum capacity of 350mA 35 amp 2 7 Red X X Common terminal Provides common ground for the 12 VDC power and signa...

Page 13: ...on Signal a remote computer on the Slide door operation 13 OUT B Gray X X Auxiliary Output terminal Connected to Normally Closed contact on an internal relay 14 OUT C Violet X X Auxiliary Output termi...

Page 14: ...escription Night Night OFF ON X X Sensors on Terminal 3 and 8 can not open the door while door is closed X X Sensors on Terminal 3 and 8 will provide threshold safety when door is in any position othe...

Page 15: ...vide threshold safety only Electric Lock remains locked unless an activation occurs from the interior sensor or by a device such as a card reader key switch wall plate etc that is connected in one of...

Page 16: ...P N 14 11741 AC115V 10 50 60 Hz Auxiliary 120 VAC Power Wires These wires are normally ON OFF Power Switch BLUE U30 TERMINAL U30 MICROPROCESSOR CONTROL LABEL WHITE TERM 5 RED TERM 4 BLUE BLUE WHITE WH...

Page 17: ...YELLOW BROWN RED GRAY YELLOW WHITE GRAY BLK GRAY RED YELLOW BROWN ACUSENSOR EXTENSION HARNESS PN 22 9267 00 BLUE BLUE BLUE WHITE WHITE WHITE WHITE MAGNETIC POWER DOWN SWITCH P N 22 9222 WHITE WHITE BL...

Page 18: ...HARNESS P N 22 9267 00 OPTEX HOLDING BEAM CONTROLLER PT NO P N 14 9710 03 TERM 1 RED BROWN RED BROWN BLK RED GRAY YELLOW YELLOW GRAY RED RED BLUE RED ORANGE ORG WHT ORG WHT RED GREEN RED ORANGE RED OR...

Page 19: ...ED BROWN RED BROWN BLK RED GRAY YELLOW YELLOW GRAY RED RED BLUE RED ORANGE ORG WHT ORG WHT RED GREEN RED ORANGE RED ORG WHT BLUE GREEN ORANGE Optex OS 12C Controller 20VAC 50 60Hz Microprocessor Contr...

Page 20: ...BROWN RED BROWN BLK RED GRAY YELLOW YELLOW GRAY RED RED BLUE RED ORANGE ORG WHT ORG WHT RED GREEN RED ORANGE RED ORG WHT BLUE GREEN ORANGE Optex OS 12C Controller 20VAC 50 60Hz Microprocessor Control...

Page 21: ...Microprocessor Controller 248901 GYRO TECH HOLD OPEN NIGHT ONE WAY TWO WAY MODE M1 M0 Open Gnd Open Open Open GndG nd Gnd Mode SW Usage Adjustments to the door can only be made with the NABCO Handy T...

Page 22: ...Collector 5Amax 0 20V 3 2Amax 20 30V 30V 42 4Vpeak max Contact Output Class2 Load only 12VDC Common FUNCTION SLIDING DOOR Reduced Opening Switch Breakout Detector Sidelite Presence Sensor Exterio r Ac...

Page 23: ...ion of Infrared Light Beams A pulsed infrared light beam is used to continuously transmit across the Slide door opening Interruption of the infrared light beam will switch the White holding beam input...

Page 24: ...eak max Contact Output Class2 Load only 12VDC Common FUNCTION SLIDING DOOR Reduced Opening Switch Breakout Detector Sidelite Presence Sensor Exterio r Ac va on Holding Beam Interior Ac va o n 12VDC Co...

Page 25: ...a signal from a Remote Switch Transmitter Activation Device on the face of the Door Electric Locks are pre installed at the NABCO Factory Only the Strike mounted on the Header may need to be adjusted...

Page 26: ...OR P N 24 11327 U30 CONTROL P N 24 8901 30 POWER SUPPLY P N 14 11741 GROUND HARNESS P N 14 11872 POWER SUPPLY HARNESS P N 14 11874 VIOLET GRAY TERMINAL ON U30 MAIN HARNESS P N 24 11877 WIRING FOR ELEC...

Page 27: ...n Open Open Gnd Gnd Gnd Mode SW Usage Adjustments to the door can only be made with the NABCO Handy Terminal CAUTION To maintain warranty repairs must be made by authorized NABCO facilities Do not dis...

Page 28: ...CK RED RED BLACK BLACK BLUE BROWN WHITE Some magnetic locks as well other types of locks require a voltage suppression device such as a diode or MOV Connect here if needed Read the instructions provid...

Page 29: ...16 No 11 10 9 8 7 6 5 4 3 2 1 RELATED DEVICES 16P 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 Contact 1 Contact 2 Mode Contact 1 Contact 2 Two Way Auto Open Open One Way Mode Exit Only Open Closed Night M...

Page 30: ...s Do not disassemble the control box There are no user serviceable parts inside POWER 2P INDICATORS 61 6B H 62 BA POWER ERROR MOTOR 12P No WARNING To protect against risk of fire or electric shock use...

Page 31: ...DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out A Out B Out C Out 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Related Devices 16P 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DN 0545 NON SECURE ACTIVATION DEVICES SUCH...

Page 32: ...d position Note if second door is another Nabco sliding door then relay is not required Two Sequential Door Operation Instructs the relay to turn ON thereby sequentially activating a second Slide door...

Page 33: ...l not operate X X Check that the power down magnet in the top rail of the Breakout panel is installed and aligned with the magnetic power down switch in the bottom of the Header X X Confirm Rocker Swi...

Reviews: