18 of 32
Opus Control Wiring and Programming Installation Manual
www.NabcoEntrances.com
P/N C-00139
Rev 10-20-17
CHAPTER 11: SWING DOOR WIRING DIAGRAMS
SECTION 11.1: Activation
DN 1329
14
13
12
11
10
9
8
7
6
5
4
3
2
1
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Exterior Push-Plate
Interior Push-Plate
COM
N.O.
3
2
4
COM
N.O.
All Devices Must Be
N.O. Dry Contact
Powered Activation Devices
(sensor, card reader, radio receiver, etc.)
Powered Activation Devices
Non-Powered Activation Devices
WARNING!
Total Power Consumption Of All Sensors And Powered Activation
Devices Must Not Exceed 750 mA
7
6
5
4
3
2
1
3
2
4
All Device Outputs Must Be
N.O. Dry Contact
7
6
5
4
3
2
1
CO
.O.
PWR+ PWR-
1
CO
.O.
PWR+ PWR-
Exterior Activation
Interior Activation
RADIO
RECEIVER
1
12VDC +12VDC
2
GND
Common for 12V and Signals
3
61
Interior Ac va on
4
62
Exterior Ac va on/Programmable Input
5
6B
Swing Door Con nuous Safety (door mounted, swing side Safety Sensor)
Slide Door
Holding Beam
6
SWL
Swing Door Safety with Lockout (overhead, swing side safety sensor)
Slide Door
Sidelite Sensor
7
Out1 Programmable Output
N
M
N
M