28 of 32
Opus Control Wiring and Programming Installation Manual
www.NabcoEntrances.com
P/N C-00139
Rev 10-20-17
SECTION 11.11: Other
DN 1333
14
13
12
11
10
9
8
7
6
5
4
3
2
1
14
13
12
11
10
9
8
8 BA Break-out, Used mainly for sliding doors, can be used for ON/OFF with swing doors.
9 SQ Sequential activation. Signal to open, Signal to close.
10 H Programmable input
11 M0 Mode 0, When grounded, puts door into "One-Way" Mode, ("Hold-Open" when grounded with M1)
12 M1 Mode 1, When grounded, puts door into "Night" Mode, ("Hold-Open" when grounded with M0)
13 Out2 Aux. Output 2, Programmable output, closes to GND
14 GND Ground (common) for all above signals
For connecting to a
second Opus for
Sim-Pair, Astragal,
Sequencing
14
13
12
11
10
9
8
10
14
Example of a switch being used to turn
on/off Power-Close and Hold Closed.
Programmable input "H" (terminal 10)
would be set "Spring Close Only".
To see other options for the
programmable input, see programming
and input settings.
PROGRAMMABLE INPUT
SECTION 11.12: Motor Wiring
11.12.1 GT300/400/500/600/1400
DN 1315
ENCODER MOTOR WIRING
NONENCODER WIRING
Handing Harness
(Right Hand Units)
To Opus Control
To Motor
To Motor
Non-Encoder
Adapter Harness
To Opus Control
Motor
Harness
To Door
Posi on Switches
Brake Module
11.12.2 GT710/8710
DN 1327
ENCODER MOTOR WIRING
NONENCODER WIRING
Non-Encoder Adapter Harness
To Motor
To Motor
To Opus Control
2
1
1
2
To Door Posi on
Switches
Motor Harness
2
1
1
2
Motor Fuse
To Opus Control
Motor Harness
Motor Fuse