6 of 32
Opus Control Wiring and Programming Installation Manual
www.NabcoEntrances.com
P/N C-00139
Rev 10-20-17
CHAPTER 6: THE OPUS CONTROL
The Opus Control is used to power and control operating characteristics of the door with the use of harnesses and wiring.
Note: When the LCD Screen is LIT, the Hold Close feature is disabled. When the LCD screen is OFF, the Hold Close feature is
enabled.
Figure 1 Opus Control
DN 1328
①
②
③
④
⑤
⑥
⑦
⑧
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1 CN3
I/O Terminal Strip
5
-
LCD Screen
2 CN5
Relay Output Terminal Strip
6
CN2
Motor Connector
3
CN4
CAN Bus Communication
7 CN1
Power Connector
4 -
Rotary Dial
8 -
Fuse
CHAPTER 7: THE ROTARY DIAL
X
X
Push down on the Rotary Dial:
•XLong push (2) seconds to gain access to LCD Catagory Screens.
•XShort push under (2) seconds to access Sub-level screens, and to selected/unselect menu items.
•XLong push (2) seconds to go back to Level Two or Level One screens.
X
X
Turn the Rotary Dial (2) clicks to advance through each menu item:
•XClockwise: To scroll forward through screens and programming options.
•XCounterclockwise: To scroll backward through screens and programming options.
DN 1242
Type:
GT710 Swing
Status:
Slow Closing
Error:
-----
Ac va on: IN EXT
Switch:
LCHK BCHK
Other:
BA 6B SWL
Push and Hold Dial
Go to Se ng Mode
Rotary Dial
UNIT SPECIFICATIONS
11
20
10
12
LCD Screen
Figure 2 The Rotary Dial