CHAPTER 8: LCD CATAGORY SCREENS
Passcode
Go to Se ng Menu
Stroke Learning
Yes No
UNIT SPECS
ERROR
ANSI
TERMINAL
Long
Push
LEVEL 1
LEVEL 2
Rotate Dial to navigate screen. Short Push Dial to select
Se ng Category
LEVEL 3
Parameter
Op ons
Base Se ng
Operator Type/Low or Full Energy/Handing/Encoder
Movement Se ng
(Rotate Rotary Dial)
Open Speed/Back Check Speed/Back Check Range/Close Speed/Latch Check Speed/
Latch Check Range/Open Timer/Reac on Power/Open Recycle Sens/Close Recycle Sens/
A er Open Recycle
Op onal Se ng
Hold Close Force/Power Close Range/Manual Open Func on/Manual Open Sens/Manual
Open Timer/BCHK Lockout Angle/LCHK Lockout Angle/Stop Force adjustment/SimPair Se ng
Output Se ng
Output1 Se ng/Output2 Se ng/RelayOutput3 Se ng/Open Delay Timer/
Sequence Delay Timer/Lock Condi on
Input Se ng
Input 62 Se ng/Input 62 Open Timer/Input H Se ng/Input H Open Timer/Input 61 Circuit/
Input 62 Circuit/Input 6B Circuit/Input SWL Circuit/Input BA Circuit/6B Stop Closing/A er 6B
Open?/61 Monitoring/62 Monitoring/6B Monitoring/SWL Monitoring
History Se ng
Opera on Cnt/Open Recycle Cnt/Close Recycle Cnt/Latest Recycle Posi on
DN 1334
LEVEL 4
Push and Hold Rotary Dial (2 Sec.)
Rotate
Dial
Rotate
Dial
Rotate
Dial
Short
Push
Figure 3 LCD Screen Transition
SECTION 8.1: Level One: Specification Screens
Type:
GT710 Swing
Status:
Slow Closing
Error:
-----
Ac va on: IN EXT
Switch:
LCHK BCHK
Other:
BA 6B SLS
Keep Pushing Switch
=> Se ng Mode
DN 1241
UNIT SPECS
ANSI specs (reference)
Opening Time to 80 deg
Closing Time to LCHK
LCHK to FullClosed
8
BA
1 12VDC
9
SQ
2 GND
10 Mul
3 61
11 M0
4 62
12 M1
5 6B
13 Out3
6 SWL
14 GND
7 Out2
Terminal
Error Screen
Mfg: 11/2016 Rev.B:21
Rotate
Dial
Rotate
Dial
Rotate
Dial
ANSI SPECS
ERROR SPECS
TERMINAL SPECS
Figure 4 Level One Screens
Level One screens are used to inform the User all specifications that have already been programmed into the Opus Control. If a
specification needs to be changed, the User must reprogram the Opus Control within the Level Three screen, or Level Four screen.
When Power is turned ON for the first time, the Door does not move. Instead, an LCD screen will illuminate to display a Level One:
Unit Specification screen (Default screen). There are (4) Level One screens:
X
X
Unit Specifications:
•XDisplays the type of door and current status of the unit. The type of door (swing, slide or folding) can be changed
within the Base Settings Category (Level 3 and Level 4). Please refer to Subsection Table►5 The screen above
shows the Opus control installed on a GT710.