3.1.3 Wire Rope Inspection
3.1.3.1
Wire rope inspection should be conducted according to the manufacturer’s recommendations
or accepted industry standards.
ACTUAL
DIAMETER
CORRECT MEASUREMENT
INCORRECT MEASUREMENT
THE WIRE ROPE MUST BE REPLACED IF THE DIAMETER MEASURES LESS THAN
THE MINIMUM DIAMETER GIVEN BY THE ROPE MANUFACTURER
EXAMPLE - A
3
4
" WIRE ROPE HAS A MINIMUM DIAMETER OF
45
64
" (0.7031")
FIGURE #8 - WIRE ROPE DIAMETER
CAUTION
Remember to always wear the proper protective equipment when handling the wire rope.
3.1.3.2
Inspect the entire length of wire cable for bent or crushed areas, broken or cut wires,
corrosion and other damage. If any defect or damage is found the cable must be replaced.
3.1.3.3
Inspect end connections and fittings for corrosion, kinking, crushing or other damage. If any
corrosion or damage is found the cable must be replaced.
3.1.3.4
Check the wire rope diameter for signs of decreased area (see fig. #8). Diameter decrease
may be signs of wear and internal degradation in the wire rope. Generally, wire ropes
are manufactured larger than nominal diameter. When placed in service for the first time,
diameter can reduce slightly. Minimum diameter specifications can be obtained from the rope
manufacturer.
Summary of Contents for DF-356-UFW
Page 1: ...OM DF356FST 001 A NABRICO DF 356 Upfit Winch with FASST WinderTM Owner s Manual ...
Page 2: ...THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 21: ...21 NABRICO DF 356 Upfit Winch with FASST WinderTM Owner s Manual OM DF356FST 001 A ...
Page 26: ...26 NABRICO DF 356 Upfit Winch with FASST WinderTM Owner s Manual OM DF356FST 001 A ...
Page 27: ...27 NABRICO DF 356 Upfit Winch with FASST WinderTM Owner s Manual OM DF356FST 001 A ...