4.4 Change of the Network Environment
4-22
4.4 Change of the Network Environment
To reconstruct the network environment by changing the IP address of master or slave, another operation
different from the initial setting operation is necessary.
Note that this operation can be completed by resetting on the robot controller side if not changing the IP
address.
4.4.1 Resetting of the fieldbus and EtherNet/IP (master and slave)
Change “4.2.1 Fieldbus settings”, “4.3.2 EtherNet/IP (Master) Settings” and “4.2.2 EtherNet/IP (slave) settings”
if needed. For detailed operation, refer to each chapter.
Resetting on the robot controller side
1
Select <Constant Setting> - [8 Communication].
2
Select [3
Fieldbus
].
If any change has been made, make a setting.
>>Refer to “4.2.1 Fieldbus settings”.
3
Select the channel to change, and press <
Refer
> button.
Change the appropriate items of the master and slave.
If the IP address has been changed, set "Execute Mode" of master to “Configuration”.
>> Refer to “4.3.2 EtherNet/IP (Master) Settings”.
>> Refer to “4.2.2 EtherNet/IP (slave) settings”.
4
Press <Complete> on the fieldbus setting screen.
If the IP address has been changed, continue to make a resetting of Scanlist.
If the IP address has not been changed, resetting operation is now completed.