4.2 Setting of parameters
4-15
4.2.8 Setting the Safety network parameters (RMU20-40)
This screen is displayed only for RMU20-40.
1
Open <Constant Setting> - [3 Machine constants]
–
[34 Robot monitoring
unit]
–
[1 Setting]
–
[9 Safety network parameters].
>> The following screen will be displayed.
2
Set the required parameters with reference to the Table 4-9.
IMPORTANT
If the RMU was replaced, press the "Complete" key even if there are no changed
parameters.
3
After setting, press f12 <Complete>.
>> When setting is done correctly, following message is displayed. But this is
normal. After closing this message with [R] key, perform the confirmation
operation.
Table 4-9 Setting items for the safety network parameters
Parameter
Description
Default
Safety
inputs/outputs
This is a Disable/Disable switch for the safety network function.
To use this function, select "Enabled".
Disabled
Input bytes
Set the input size of the I/O in bytes. (This is fixed to 8)
8
Output bytes
Set the output size of the I/O in bytes. (This is fixed to 8)
8
F Destination
address
Set the address of the RMU that is used for the PROFIsafe.
The “F Destination address” is a parameter to identify the device on the
PROFISafe network and must be set separately from the IP address that
is used for the PROFINET. The identical address cannot be set in the
identical network.
200
Operator class
SPECIALIST
is necessary to change these parameters.
Summary of Contents for RMU20-20
Page 2: ......
Page 6: ...Contents 4 ...
Page 8: ......
Page 26: ...1 4 EC DECLARATION OF CONFORMITY FOR MACHINERY 1 18 NOTE ...
Page 68: ...2 9 Enabling RMU 2 40 NOTE ...
Page 70: ......
Page 100: ...3 4 Setting when a slider unit is used 3 30 NOTE ...
Page 102: ......
Page 138: ...4 4Approval 4 36 8 Approval is completed The following screen will be displayed ...
Page 144: ......
Page 154: ...5 4Trouble shooting 5 10 NOTE ...
Page 156: ......
Page 166: ...6 4Trouble shooting 6 10 NOTE ...
Page 168: ......
Page 189: ......