5.1 Outline of the EtherNet/IP safety network function
5-3
Network safety plug signal
By assigning this signal, it becomes possible to get the safety plug input signal from the safety network.
If this signal is assigned, this signal must be kept ON to playback the robot program.
If "0" is set, this function is disabled.
Network protective stop signal
By assigning this signal, it becomes possible to get the protective stop input signal from the safety network.
While this signal is not ON, the Motors will not turn ON. However, only in TEACH mode, the protective stop
signal can be enabled/disabled using the setting item of "
Teach protect stop
".
(For details, refer to "4.2.4 Setting of signal parameters").
If "0" is set, this function is disabled.
Network external enable signal
By assigning this signal, it becomes possible to get the external enable input signal from the safety network.
If this signal is not ON, the Motors cannot be turned ON in the TEACH mode.
If "0" is set, this function is disabled.
Network remote mode signal
It is possible to change the robot controller's operation mode using the safety network signals.
The operation mode can be changed using the combination of the following signals.
"NetWork remote sig."
(Network remote mode signal)
"NetWork Ext. teach sig."
(Network external TEACH signal)
"NetWork Ext. playback sig."
(Network external PLAYBACK signal)
"NetWork Ext. H-teach sig."
(Network external High-speed TEACH signal)
If the "Network remote mode signal" is OFF, the mode selection switch on the robot controller becomes
"Enabled" and if the signal is ON, the mode selection using the safety network signals becomes "Enabled".
Concerning the signal combinations, refer to the Table 5.2-1
Table 5.2-1 The combinations of the remote mode selection using the network signals
Network remote
mode signal
Network external
TEACH signal
Network external
PLAYBACK signal
Network external
Hi-speed TEACH
signal
TEACH mode
ON
ON OFF OFF
PLAYBACK mode
ON OFF ON OFF
Hi-speed TEACH
mode
ON
ON OFF ON
CAUTION
Even if the mode is changed using the "Network remote mode signal", it is not possible to
turn ON the motor power if the teach pendant's "TP SELECTOR SWITCH" is not set to
proper position.
Summary of Contents for RMU20-20
Page 2: ......
Page 6: ...Contents 4 ...
Page 8: ......
Page 26: ...1 4 EC DECLARATION OF CONFORMITY FOR MACHINERY 1 18 NOTE ...
Page 68: ...2 9 Enabling RMU 2 40 NOTE ...
Page 70: ......
Page 100: ...3 4 Setting when a slider unit is used 3 30 NOTE ...
Page 102: ......
Page 138: ...4 4Approval 4 36 8 Approval is completed The following screen will be displayed ...
Page 144: ......
Page 154: ...5 4Trouble shooting 5 10 NOTE ...
Page 156: ......
Page 166: ...6 4Trouble shooting 6 10 NOTE ...
Page 168: ......
Page 189: ......