5.3Settings for the safety PLC
5-5
6
Select "Generic EtherNet/IP Safety Module" in the "Select Module Type".
7
Make the setting of the Module.
- "Name" : Set a plain name.
- "Description" : Write descriptions freely.
- "IP address" : Set the IP address of the RMU.
8
Make the setting of network parameters. Press the "Change..." button.
- Set the following values.
Item
Value
Vendor 441
Product Type
140
Product Code
1
Major revision
1
Minor revision
1
Electric Keying
Exact Match
Input Data
Safety
Output Data
Safety
Data Format
Integer-SINT