6.2Setting for
6-2
6.2
Setting for PROFINET module
6.2.1
Fieldbus settings
Protocol settings
1
Open <Constant Setting> - [8 Communication] - [3 Fieldbus].
2
Align the cursor with the combo box of a channel which is going to use the
PROFINET safety, and press [Enter] key.
>>Select the [PROFINET Safety] using the cursor key and press [Enter] key.
3
Align the cursor with the "Slot ID" combo box, and press [Enter] key.
Select the Slot ID where PROFINET board is mounted and press [Enter] key.
>> The slot ID is required in order to check the position where the board has been
installed. Concerning the relationship between the slot position and the slot ID, refer to
the following picture.
1 2 3
Slot ID