6.4Trouble shooting
6-8
6.4 Trouble
shooting
6.4.1
Trouble shooting via the LEDs
The PROFINET module shows its present condition using 3 LEDs.
Hilscher PROFINET module comX
The LED status and PROFINET SLAVE module (comX) status
LED
Color
Condition
Remarks
Green
Lit
Normal
The Operating System is running.
Green/
Yellow
Flashing
Stand-by
Waiting for the firm-ware start
Yellow
Lit
Start failed
Firm-ware start failed
LED1
-
Unlit
Offline
The power is not supplied.
Red Lit
System
error
Error occurred in the system. Please check the
setting parameters. If this error remains after
changing the wrong parameters, please replace
the PCB.
Red
Flashing
DCP Signal
DCP Signal was received from the master device.
LED2
-
Unlit Normal
No
error
Red Lit
Connection
failed
Not connected or the network communication
speed is not fast enough. Please check the
network cables etc.
Red Flashing
No data
communication
No I/O communication. Please check that the
PROFINET Controller is working normally.
LED3
-
Unlit Normal
No
error
If the all LEDs are normal, it means that the device is operating normally as a PROFINET device.
But it does not mean that the device is operating as a PROFIsafe device also.
In a case like that, please check the error code displayed on the teach pendant screen also.
LED
Channel 0
Channel 1
Ethernet IF
Either channel can
be used.
LED3
LED2
LED1
LED1 : Module status
LED2 : Ethernet connection status
LED3 : IO connection status
Summary of Contents for RMU20-20
Page 2: ......
Page 6: ...Contents 4 ...
Page 8: ......
Page 26: ...1 4 EC DECLARATION OF CONFORMITY FOR MACHINERY 1 18 NOTE ...
Page 68: ...2 9 Enabling RMU 2 40 NOTE ...
Page 70: ......
Page 100: ...3 4 Setting when a slider unit is used 3 30 NOTE ...
Page 102: ......
Page 138: ...4 4Approval 4 36 8 Approval is completed The following screen will be displayed ...
Page 144: ......
Page 154: ...5 4Trouble shooting 5 10 NOTE ...
Page 156: ......
Page 166: ...6 4Trouble shooting 6 10 NOTE ...
Page 168: ......
Page 189: ......