1.1 Outline
1-12
1.3.4 Connection of safety inputs
Electrical
specifications
Rating DC26V, 5mA max
Connect the relay contacts (dry contacts).
To prevent defective contact and other problems, use a device which can turn on and off
the very small load specified above.
These input signals must have redundant circuit. The two separat signals with redundant contact inputs must
perform identical operations. Connect separate contacts between pins "INA+" – "INA-" and "INB+" – "INB-" for
each input as shown in the Fig.1-2. Bear in mind that the signals cannot be connected in ways such as the one
shown in Fig.1-3.
[Example] In case of robot emergency stop inputs
Fig.1-3 Connection diagram of safety input signals
Fig.1-4 Example of how the safety input signals cannot be connected
Connection of monitor input
Electrical
specification
Rating DC26V, 5mA
Connect the dry contacts.
To prevent defective contact and other problems, use a device which can turn on and off
the very small load specified above.
Fig. 1-5 Connection diagram of the monitor input signal
External input
External input
TBX-1 (RMU input)
TBX-1 (RMU input)
External input
TBX-1 (RMU input)
External input
TBX-1 (RMU input)
Summary of Contents for RMU20-20
Page 2: ......
Page 6: ...Contents 4 ...
Page 8: ......
Page 26: ...1 4 EC DECLARATION OF CONFORMITY FOR MACHINERY 1 18 NOTE ...
Page 68: ...2 9 Enabling RMU 2 40 NOTE ...
Page 70: ......
Page 100: ...3 4 Setting when a slider unit is used 3 30 NOTE ...
Page 102: ......
Page 138: ...4 4Approval 4 36 8 Approval is completed The following screen will be displayed ...
Page 144: ......
Page 154: ...5 4Trouble shooting 5 10 NOTE ...
Page 156: ......
Page 166: ...6 4Trouble shooting 6 10 NOTE ...
Page 168: ......
Page 189: ......