2.5 Operating Range, Angle and Speed Monitoring Function
2-30
When using the tool number monitoring function, prepare a tool that can output 4 bit binary output signals to
output the tool number. Connect the signals from the tool to the "Tool No. 1 -4" on the terminal block TBX-1 in
the robot controller as follows;
P1(24V)
ツール番号1
ツール番号2
ツール番号3
ツール番号4
監視ユニット
TBX-1
ツール Tool
制御装置
お客様施工範囲
For details of how to make this connection, refer to the section of "1.3 Connection".
Controller
Connections to be made by customer
Robot Monitoring Unit
Tool No. 1
Tool No. 2
Tool No. 3
Tool No. 4