background image

ENGLISH

7

PROBLEM

POSSIBLE CAUSE

The platter doesn’t turn although the unit is switched on.

•  The unit is not connected to the mains power supply.
•   No mains power is being delivered at the socket.
•  The drive belt is not fitted properly or has slipped off.

One or both channels have no output signal.

•  No signal contact from the cartridge to any of the following - internal 

tonearm wiring, arm lead, phono box; or to the amplifier. 

•  Faulty plug, broken wire or loose solder joint in the plug/socket 

connection. 

•  Phono input not selected at amplifier.
•  Amplifier or speakers are defective or muted.
•  No connection to the loudspeakers. 
•  Amplifier not switched on.

There is strong hum on phono input.

•  No ground connection from cartridge, arm or arm cable to amplifier or 

ground loop.

Sound is distorted or inconsistent from one or both channels.

•  Turntable is connected to wrong input of amplifier or MM/MC switch is 

incorrectly set. 

•  Needle or cantilever is damaged. 
•  Wrong rpm setting.
•  Drive belt is overstretched or dirty.
•  Platter bearing needs lubrication, dirty or damaged.

TROUBLESHOOTING

Summary of Contents for C 588

Page 1: ...Owner s Manual ENGLISH Turntable C588...

Page 2: ...unit exhibits a marked change in performance The unit has been dropped or the cabinet has been damaged DO NOT ATTEMPT TO SERVICE THE UNIT YOURSELF NOTES ON ENVIRONMENTAL PROTECTION At the end of its u...

Page 3: ...for single LP s Allen keys 1 5mm and 2mm for possible setting of the tonearm Stylus pressure gauge Plastic tool for tonearm bearings Paper cartridge alignment tool with two null points Black felt mat...

Page 4: ...r Hinges 10 Hinge Fasteners 11 Counterweight 12 Tonearm 13 Tonearm Lift 14 Tonearm Rest And RemovableTransport Lock 15 Anti Skating Adjustment 16 Headshell With Finger Lift 17 Damped Feet 18 RCA Outpu...

Page 5: ...ing Force VTF 2 Push the counterweight carefully towards the rear end of the counterweight support rod Place the stylus pressure gauge onto the platter 3 Set the required VTF by lowering the tonearm l...

Page 6: ...the azimuth set screw 2 Loosen the screw just enough to gently rotate the arm tube and set the azimuth to the correct position The correct position can be checked from the front view preferably with t...

Page 7: ...g broken wire or loose solder joint in the plug socket connection Phono input not selected at amplifier Amplifier or speakers are defective or muted No connection to the loudspeakers Amplifier not swi...

Page 8: ...M Effective tonearm mass 9 5 g Effective tonearm lenght 230 mm Overhang 18 mm ORTOFON OM 10 CARTRIDGE Frequency range 20 Hz 22 kHz Channel separation 22dB 1kHz Output voltage 5 5 mV Recommended load i...

Page 9: ...ENGLISH 9...

Page 10: ...nal a division of Lenbrook Industries Limited No part of this publication may be reproduced stored or transmitted in any form without the written permission of NAD Electronics International While ever...

Reviews: