ENGLISH
6
5 LINE INPUT (1-8)
•
Use RCA-to-RCA leads to connect the LINE INPUT terminals to
corresponding Audio Output terminals of compatible external
devices such as preamplifiers, processors or other applicable
devices.
•
Configure LINE INPUT 1-8 via INPUT/OUTPUT menu of the web-
based CI 8-120 User Interface. Each LINE INPUT source can be
assigned to a specific or multiple speaker OUTPUT channel(s).
•
The LINE INPUT ports are numbered 1 to 8. LINE INPUT channels with
active input signal will have their corresponding front panel LINE INPUT
LED indicators illuminated in blue. If there is no active input signal
connected to a particular LINE INPUT, the corresponding front panel
LINE INPUT LED indicator will not light up.
6 SPEAKERS (1 - 8)
•
Connect external speaker cables to supplied SPEAKERS terminal
block ensuring that the connections match CI 8-120's SPEAKERS
terminal markings.
•
To illustrate, connect CI 8-120 SPEAKERS “1+” terminal to
corresponding “+” terminal of your external speaker and “1-”
connected to external speaker’s “-” terminal. Follow the same
connection configuration when connecting other external speakers
to SPEAKERS terminals “2+” and “2-” up to “8+” and “8-”.
•
After installing the external speaker cables to the supplied SPEAKER
terminal blocks, plug in the wired up SPEAKER terminal blocks to
corresponding SPEAKERS (1- 8) rear panel terminals of CI 8-120.
SAMPLE STEREO MODE SPEAKER CONNECTION FOR
SPEAKERS 1 AND 2
EXTERNAL
SPEAKER
TERMINAL
CI 8-120 SPEAKERS TERMINAL
SPEAKERS “1 +” SPEAKERS “1 -” SPEAKERS“2 +” SPEAKERS“2 -”
External Speaker 1
“+” terminal
✔
External Speaker 1
“-” terminal
✔
External Speaker 2
“+” terminal
✔
External Speaker 2
“-” terminal
✔
•
At Bridge Mode, connect the external single speaker to
corresponding CI 8-120 SPEAKERS terminals marked “1+” and “2+”
ensuring that “1+” is connected to the external speaker’s “+” terminal
and “2+” connected to the external speaker’s “-” terminal (This is
sample BRIDGE mode connection for SPEAKERS 1 and 2. The same
BRIDGE mode connection configuration applies for the rest of the
SPEAKERS terminal blocks).
•
Bridge Mode connection can be enabled or disabled via the INPUT/
OUTPUT menu of the web-based CI 8-120 User Interface.
SAMPLE BRIDGE MODE SPEAKER CONNECTION FOR
SPEAKERS 1 AND 2
EXTERNAL
SPEAKER
TERMINAL
CI 8-120 SPEAKERS TERMINAL
SPEAKERS “1 +”
SPEAKERS “1 -”
SPEAKERS“2 +”
SPEAKERS“2 -”
Single external
Speaker “+”
terminal
✔
Single external
Speaker “-”
terminal
✔
7 +12V TRIGGER IN
+12V TRIGGER IN – ON/OFF
•
This dual function switch alternates between sensing a +12V input
as applied through the +12V TRIGGER IN and def12V
TRIGGER IN.
•
At ON setting and with the +12V TRIGGER IN of CI 8-120 connected
to a compatible external device that is equipped with a +12V DC
trigger output, the CI 8-120 can be switched remotely from standby
mode to operating mode and vice-versa. This is dependent upon
the presence or absence of +12V DC supply at +12V TRIGGER IN
(refer also to item about +12V TRIGGER IN +/-).
•
With +12V TRIGGER IN-ON/OFF switch set to ON, the CI 8-120
cannot be powered from standby to operating mode and vice-
versa. The function of powering up/down the CI 8-120 is handled
by the compatible external device where +12V TRIGGER IN is
connected.
•
+12V TRIGGER IN is disabled when +12V TRIGGER IN - ON/OFF
switch is set to OFF. This is the default setting and allows the
CI 8-120 to power up normally.
+12V TRIGGER IN +/-
•
Use the supplied 12V TRIGGER terminal block to c12V
TRIGGER IN +/- terminals to corresponding terminals of compatible
ex12V TRIGGER source. Install the wired up 12V TRIGGER
terminal block to CI 8-120’s +12V TRIGGER IN +/- rear panel terminal.
•
The +12V TRIGGER IN allows the CI 8-120 to be remotely switched
from standby mode to operating mode and vice-versa by the
external controlling device where +12V TRIGGER IN is connected to.
The external controlling device, such as compatible preamplifiers,
integrated amplifiers, receivers, etc., must be equipped with +12V
trigger output to use this feature.
•
Refer also to the item about “12V TRIGGER- ON/OFF”.
8 LAN
•
LAN connection must be setup for wired connection to be
established. Set up a Wired Ethernet broadband router with
broadband internet connection. Your router or home network
should have a built-in DHCP server to consummate the connection.
•
Using a standard straight-through Ethernet cable (not supplied),
connect one end of the Ethernet cable to the LAN port of your
wired Ethernet broadband router and the other end to CI 8-120’s
LAN port.
NOTES
• NAD is not responsible for any malfunction of the CI 8-120 and/or the
internet connection due to communication errors or malfunctions
associated with your broadband internet connection or other
connected equipment. Contact your Internet Service Provider (ISP) for
assistance or the service bureau of your other equipment.
• Contact your ISP for policies, charges, content restrictions, service
limitations, bandwidth, repair and other related issues pertinent to
internet connectivity.
9 RESET
•
Use the RESET button to manually restore CI 8-120 to its factory
default settings.
•
While at operating mode, press and hold RESET button until
Standby LED continuously flash in amber color. Release hold of
RESET button. Factory reset is completed when the continuously
flashing amber Standby LED stops and unit goes to standby mode.
IDENTIFICATION OF CONTROLS