Current Rating
......................................................................................................................................................15 Amps
Filtered Sequenced Outlets
..............................................................................................................................................8
Sequential Zones
........Zones 1-4 (for digital equipment, 5A max.), Zone 5 (2 outlets, for analog equipment, 10A max.),
Zone 6 (2 high-power outlets,15A max.)
Filtering
..................................................................................................................................................................RFI/EMI
Sequence Delay Time
......................................................2 seconds, internally factory adjustable also to 1 or 3 seconds
Switching Response Time
..........................................................................................................................1 nanosecond
Zone Indicators
....................................................................................................................................6 LEDs, Zones 1-6.
Rack Lamp
................................................................................................Single retractable, swiveling 6-LED light fixture
Input AC Voltage
..............................................................................................................................................90~140 VAC
Voltmeter Display
........................................................................................................................................3-Digit numeric
Maximum Surge Current
........................................................................................................................................6,500 A
Dimensions
............................................................................................................19’’ x 1.73’’ x 7.5’’ (483 X 45 X 190mm)
Weight
........................................................................................................................................................8.5 lbs. (3.9 Kg)
Specifications and design subject to change without prior notice for improvement purposes
5
CONTROLS AND CONNECTIONS
(11)
(10) (9)
(8)
8.
POWER CORD
Connect power cord to AC source (120VAC, 16A minimum) before turning unit “ON”.
9.
CHASSIS GROUND
Use a wire connected from this terminal to system ground for best results and to eliminate ground
loop hum.
10.
GROUNDING INDICATOR
The LED will light to indicate good grounding status. If it doesn’t light, connect a wire from the
Chassis Ground (9)
to system ground until the LED lights.
11.
ZONE 1-6 AC OUTLETS
These outlets have three kinds of filter (digital filter/analog filter/high power), which are designed to
reduce the noise to your connected digital/analog/high current components. Zones 1-4 are rate 5A
maximum and are for connecting lower draw digital components such as a CD player, or computer.
Zone 5 (2 outlets) are rated 10A maximum and are for connecting medium power analog units such
as mixers. Zone 6 (2 outlets) is rated 15A maximum and should be used for connecting high power
components such as power amplifier. When the CPD-1006L is turned on, the digital and analog
outlets, Zones 1-5, are switched on first in 2 second sequential intervals, and then the high current
Zone 6 outlets are switched on. This delayed sequencing protects speakers connected to the
amplifiers from the turn-on noises of the equipment connected to Zones 1-5. Powering “OFF” is the
reverse sequence and protects the speakers from any turn-off noises generated by the equipment
connected to Zones 1/5.
REAR PANEL
SPECIFICATIONS