Current Rating

......................................................................................................................................................15 Amps

Filtered Sequenced Outlets

..............................................................................................................................................8

Sequential Zones

........Zones 1-4 (for digital equipment, 5A max.), Zone 5 (2 outlets, for analog equipment, 10A max.), 

Zone 6 (2 high-power outlets,15A max.)

Filtering

..................................................................................................................................................................RFI/EMI 

Sequence Delay Time

......................................................2 seconds, internally factory adjustable also to 1 or 3 seconds

Switching Response Time

..........................................................................................................................1 nanosecond

Zone Indicators

....................................................................................................................................6 LEDs, Zones 1-6.

Rack Lamp

................................................................................................Single retractable, swiveling 6-LED light fixture

Input AC Voltage

..............................................................................................................................................90~140 VAC

Voltmeter Display

........................................................................................................................................3-Digit numeric

Maximum Surge Current

........................................................................................................................................6,500 A

Dimensions

............................................................................................................19’’ x 1.73’’ x 7.5’’ (483 X 45 X 190mm)

Weight

........................................................................................................................................................8.5 lbs. (3.9 Kg)

Specifications and design subject to change without prior notice for improvement purposes

5

CONTROLS AND CONNECTIONS

(11)

(10) (9)

(8)

8.

POWER CORD 

Connect power cord to AC source (120VAC, 16A minimum) before turning unit “ON”.

9.

CHASSIS GROUND

Use a wire connected from this terminal to system ground for best results and to eliminate ground 
loop hum.

10.

GROUNDING INDICATOR

The LED will light to indicate good grounding status. If it doesn’t light, connect a wire from the 

Chassis Ground (9)

to system ground until the LED lights.

11.

ZONE 1-6 AC OUTLETS

These outlets have three kinds of filter (digital filter/analog filter/high power), which are designed to 
reduce the noise to your connected digital/analog/high current components. Zones 1-4 are rate 5A 
maximum and are for connecting lower draw digital components such as a CD player, or computer.
Zone 5 (2 outlets) are rated 10A maximum and are for connecting medium power analog units such 
as mixers. Zone 6 (2 outlets) is rated 15A maximum and should be used for connecting high power 
components such as power amplifier. When the CPD-1006L is turned on, the digital and analog 
outlets, Zones 1-5, are switched on first  in 2 second sequential intervals, and then the high current 
Zone 6 outlets are switched on. This delayed sequencing protects speakers connected to the 
amplifiers from the turn-on noises of the equipment connected to Zones 1-5. Powering “OFF” is the 
reverse sequence and protects the speakers from any turn-off noises generated by the equipment 
connected to Zones 1/5.

REAR PANEL

SPECIFICATIONS

Summary of Contents for CPD-1006L

Page 1: ...R A C K G E A R CPD 1006L Conditioned Power Distribution O W N E R S M A N U A L ...

Page 2: ...er Congratulations on your choice of the finest conditioned power distribution unit This unit was developed using the expertise of professional sound engineers and working musicians You will find that your new NADY AUDIO CPD 1006L has superior performance and greater flexibility than any other conditioned power distribution units in its price range Please read this manual carefully to get the most...

Page 3: ...oduce heat 7 The product should be connected to a power supply only of the type described in the operating instructions or as marked on the product Replace the fuse only with one of the specified type size and correct rating 8 The power supply cord should 1 be undamaged 2 never share an outlet or extension cord with other devices so that the outlet s or extension cord s power rating is exceeded an...

Page 4: ...econds contact the Nady Service Department to change internal delay adjustment The sequence for powering off will be reversed when it s switched to OFF When ON the Zone Indicators Display 4 and Voltmeter Display 5 will light up 4 ZONE 1 6 DISPLAY The LED indicators will light or turn off indicating when components connected to the ZONE 1 2 3 4 5 6 outlets are powered on and off 5 VOLTMETER DISPLAY...

Page 5: ...ght to indicate good grounding status If it doesn t light connect a wire from the Chassis Ground 9 to system ground until the LED lights 11 ZONE 1 6 AC OUTLETS These outlets have three kinds of filter digital filter analog filter high power which are designed to reduce the noise to your connected digital analog high current components Zones 1 4 are rate 5A maximum and are for connecting lower draw...

Page 6: ...6 NOTES ...

Page 7: ...Should your NADY AUDIO product require service please contact the Nady Service Department via telephone at 510 652 2411 or e mail at service nady com International For service please contact the NADY AUDIO distributor in your country through the dealer from whom you purchased this product DO NOT ATTEMPT TO SERVICE THIS UNIT YOURSELF AS IT CAN BE DANGEROUS AND WILL ALSO VOID THE WARRANTY ...

Reviews: