8
TY-EJ15-003A Rev.2
*1 The maximum allowable pressure is the upper limit of pressure value which may safely be applied to
the product and remain in specification once pressure is returned to the rated range with a couple of
times over-pressurization for about 10 minutes. Effects of continuous over-pressure are not
guaranteed.
*2 The formula showing the load resistance refers to the specification of the EJ15 alone, and it will
actually depends on the combination with the safety barrier.
*3 M12 connector type is guaranteed only when the M12-connector cable is mated. Terminal box type is
guaranteed only when the appropriate cable gland and the cables are correctly installed.
■ 3.2 Intrinsically Safe Specification
3.2.1 EJ15 intrinsically safe pressure sensor
Explosion-
proof
standards
IECEx
(International)
ATEX
(Europe)
Japan
TS
(Taiwan)
NEPSI
(China)
KCs
(Korea)
Certification
No.
IECEx CML
19.0013
CML
19ATEX2063
CML
19JPN2184
TD0502IJ
(Identification No.)
GYJ19.1315
19-AV4BO-0654
Hazardous
Area
Zone 0
Category 1G
Zone 0
Zone 0
Zone 0
Zone 0
Compliance
standards
IEC60079-0:
2017
IEC60079-11:
2011
EN60079-0:
2018
EN60079-11:
2012
JNIOSH-TR-
46-1: 2015
JNIOSH-TR-
46-6: 2015
CNS3376-0
CNS3376-11
GB3836.1-2010
GB3836.4-2010
GB3836.20-2010
IEC60079-0:2017
IEC60079-11:2011
(Notification No.
2019-15)
Compliance
directive
2014/34/EU
(ATEX Directive)
Explosion-
proof
construction
Exia II C T4 Ga
Equipment protection level
Temperature class
Gas group
Intrinsically safe construction
Safety
holding
rating
Maximum input voltage (Ui)
: 28V
Maximum input current (Ii)
: 93mA
Maximum input power (Pi)
: 651mW
Maximum internal inductance (Li)
: 0 mH
Maximum internal capacitance (Ci)
: 0.052 μF
Ambient temperature
: - 20 to 60 degrees C
External
transmissio
n
cable
Li + Lc ≤ Lo
Lc: inductance of the external transmission cable
Ci + Cc ≤ Co
Cc: capacitance of the external transmission cable
(These will vary depending on your safety barrier.)
Withstand
voltage
500V AC, one minute
* Intrinsically safe construction is achieved only when this pressure sensor is used in combination with a
safety barrier.
< Table 3-2 >