Instruction
Manual
16
9. Maintenance and cleaning
Upholstery Daily Cleaning
It is very important for the life of the upholstery to clean it properly.
1.- Clean the entire surface using a mixture of 1:9 liquid soap (neutral pH) and water. Do not use soap or cleaning solutions
that contain alcohol, ketones, xylene, acetates or solvents (mineral/white spirits).
2.- Completely remove excess cleaner with a white, clean, damp cloth.
3.- Dry the surface.
For tougher stains refer to Spradling cleaning guidelines for PERMABLOK3 & PERMAGUARD vinyl upholsteries.
- Important:
Lacquers, strong cleaners, xylene-based solutions, acetone or MEK cause immediate damage and contribute to
the deterioration of the material. The use of such cleaners is at the owner’s risk.
Table Frame Cleaning
Remove dust with a white cloth.
Use alcohol-free cleaning wipes to clean the structure or simply use a white cotton cloth soaked in a mix of water with neutral
diluted soap and rinse. Dry with a clean cloth.
Maintenance
Naggura tables have been designed for an intensive use during long time thanks to their stability, reliability and durability.
However, we advise to keep the table in perfect conditions and make a correct use of it. Unplug the table if you will not use it
for a long period of time.
Environment information
This symbol indicates that some electrical components or materials can be reused and/or are harmful to the environment
and thus, they must be properly recycled. Ensure that you are familiar with the local rules and regulations regarding to the
disposal of equipment and accessories.
10. Troubeshooting
Squeaking noise when moving the bed up & down (mechanical noise):
• The axes are adjusted and greased from factory but with the time and use, they may need some little adjustement. Remove
the grey plugs of the connecting rods (2 at each side, so 4 in total). Loosen the axes a litlle bit by unscrewing them (approx. 2
turns). Apply a bit of neutral grease and plug them again.
None of the motors work:
• Check if the power cable is disconnected, either from the wall socket or the control box.
• Check the power cable for any damage.
• Check all the plugs and connections.
• Check if the LED light in the control box is lightened GREEN.
If 1 motor is faulty:
• Follow the TEST to determine whether the source of the problem lies in the control box, the hand controller or motor of the
affected part. Exchange the cable of the faulty motor with another section that works properly to discard.
GET acces to the control box. The control box has the connections of the hand controller, the 4 engines of the bed and the
power supply cable.
If the motor of the backrest does not work, unplug for example the HEIGHT motor and plug this wire in the BACKREST motor
socket (exchange socket from other motor that works fine). Check the movement of the HEIGHT motor by pressing the but-
tons of the BACKREST movement in the hand controller.
7Observe the motor operation.
-
If the motor does not work, the problem is the motor.
-
If the motor works properly, the problem would be the control box.