Instruction 

Manual

4

Before using the treatment table, please read the instruction manual carefully. It is important to keep this manual and store it in a 

safe place so that it can be consulted at any time.

By carefully following these instructions  you will be able to avoid any problems in using the treatment table. 

Some texts and/or illustrations may not belong to your Naggura table since they are general and  it depends on your product choice 

at the purchase time.

2. Use of the Manual

The warranty period is effective on the date of purchase of the treatment table for a period of two (2) years. It covers all the compo-

nents of the treatment table under the normal and correct use. It also covers defects in workmanship from factory.

The above-mentioned warranty does not cover defects or malfunction caused by:

- Misuse, abuse or improper maintenance of the table and its upholstery;

- Non-observance of the precautions and warnings stated in this instruction manual;

- Lack of maintenance or repair tasks carried out by non-qualified service personnel who are unauthorized by the manufacturer; 

- Wrong and faulty electrical installations or which do not fulfil the legal requirements; 

- Naggura company is not liable for incidental or consequential damage to property or business.

3. Warranty

Under any circumstances, the producer shall be liable for any indirect, special, incidental or consequential damage incurred by the 

user, the patient or the table  itself as a result of:

a. A wrong diagnosis;

b. Incorrect use of the table or any of its accessories;

c. The wrong interpretation or non-observance of this user manual;

d. A lack of maintenance of the table;

e. Or maintenance works of the table and/or repairs performed by persons unauthorized to do so by the manufacturer.

According to the current legislation, the manufacturer cannot be held responsible for any flaws in the table or its components and 

accessories after a period of ten (10) years from the date on which the producer puts into circulation the actual product. Therefore, 

producer cannot be obliged to supply any spare parts or accessories for this table.

4. Product Liability

Provided that the operator and user takes care of the table and undertakes regular maintenance tasks as described in section 9 of 

the current manual, the expected lifespan of the Naggura table can reach over 10 years from production date.

The intended use of the Treatment Table is to position a patient for the treatment. The unit is intended for use by qualified professio-

nal within a professional setting.

Expected lifespan

Summary of Contents for Swop Physio

Page 1: ...Swop Physio Swop Physio VERSION 1 2 Treatment Tables for Physiotherapy SWOP2 SWOP2L SWOP2W SWOP3 SWOP5 Instruction Manual EN...

Page 2: ...atures Operation Wheel Block Unblock system Lever to adjust the headrest Breather hole and plug Handlebar support Hand controller Twinlift Space Ball perimeter foot switch Switches for lumbar flexion...

Page 3: ...will more than fulfil your most demanding work requirements NAGGURA s experts are in the lead of a project created with great devotion Every single detail has been cared to join technology performance...

Page 4: ...ts Naggura company is not liable for incidental or consequential damage to property or business 3 Warranty Under any circumstances the producer shall be liable for any indirect special incidental or c...

Page 5: ...er Place the table in a space with free access from the 4 sides Do not place the table against the wall or against any obstacles Do not use the table in a high humidity environment or in so called wet...

Page 6: ...table on a stable and horizontal surface Level it if necessary with the levelling feet under the table Guide the backrest section with the other hand when adjusting the backrest by gas levers Ensure...

Page 7: ...Instruction Manual 7 Swop 2 Swop 2L Swop 3 Swop 5 Swop 2W 7 Product dimensions...

Page 8: ...Instruction Manual 8 Handling and transport...

Page 9: ...m 250 cm Lateral displacement cm Power cord length cm Product dimensions Voltage and frequency input shall be 220 240V 50 60Hz Plug the table cable into the socket as shown below 8 Operation Power inp...

Page 10: ...g 4 Handlebar support 5 Twinlift 6 Space Ball perimeter foot switch 7 Switches for lumbar flexion 8 Lever to adjust the backrest 9 Paper roll holder 10 Side widening supports 11 Safety lock 12 Interch...

Page 11: ...oints are part of the same platform located under the table base The Space Ball perimeter switch works as follows if the therapist is located in one side of the table pull or push the activating point...

Page 12: ...nt temperature 0 C 40 C Relative humidity 30 90 Loading capacity 200 Kg Specifications 7 Switches for lumbar flexion If your Swop is a 2 engine table Swop3 and Swop5 the middle section lumbar flexion...

Page 13: ...e is locked and all the electrical systems are disabled The safety key can only be removed when the safety lock is in OFF position All SWOP physio models are fitted with a motor with an automatic clut...

Page 14: ...mood or however you feel today The exchangeable panels are 2 units one for one side of the table base and the other for its opposite The available panels are made of different materials metal wood and...

Page 15: ...Mood is installed an additional hand controller is provided to select your beloved colour to adjust the intensity of light or to change the lighting mode LED lighting Cromo Mood If you purchased the B...

Page 16: ...e is cleaned every day Clean the en tire surface using a mixture of 1 9 liquid soap neutral PH and water Do not use soap or cleaning solutions that contain alcohol ketones xylene acetates or solvents...

Page 17: ...is shown in the picture to turn the bed to one side without da maging the Space Ball perimeter switch Take the decorative panel in the base out and screw the L shaped plates in the same threaded holes...

Page 18: ...me operation with the second gas lift The up and down motor does not work Check if the power cable is disconnected either from the wall socket or the control box Check the power cable for any damage C...

Page 19: ...rade if proper distance is not maintained Guidance and Manufacturer s Declaration Electromagnetic Immunity Immunity Test IEC 60601 1 2 Test level Compliance level Electrostatic discharge ESD IEC 61000...

Page 20: ...28 V m 28 V m 710 MHz 745 MHz 780 MHz Pulse Modulation 217Hz 0 2W 9 V m 9 V m 810 MHz 870 MHz 930 MHz Pulse Modulation 18Hz 2W 28 V m 28 V m 1720 MHz 1845 MHz 1970 MHz Pulse Modulation 217Hz 2W 28 V m...

Page 21: ...Instruction Manual 21 Our products are subject to continuous technical improvements Naggura reserves the right to change or modify the product and contents without prior notice...

Page 22: ...www naggura com Pol Ind La Valldan Cam de Garreta 92 08600 Berga Barcelona Spain T 34 93 824 90 20 E info naggura com...