Instruction 

Manual

5

Naggura products are produced and marked in conformity with the directives hereby stated :

Low voltage : 2014/35/CE

Electromagnetic compatibility : 2014/30/CE   

These products are manufactured according to the essential requirements established in the European Medical Devices Directive 

(Annex II+III of Regulation (EU) 2017/745):  

EN ISO 14971:2019; EN ISO 204117:2021; EN ISO 15223-1:2016; ISO 10993-1: 2018; EN ISO 10993-5:2009; EN ISO 109933-10:2013; EN 

60601-2-52:2010+AC:2011+A1:2015; EN 60601-1-2:2015+A1:2020; EN 60601-1:2006+A1:2013+AC:2014+A12:2014+A2:2020.

The Swop line has a guarantee

 of two (2) years in all parts.  The manufacturer will not be held responsible for the results of mainte-

nance or repairs performed by unauthorised persons. 

For further information on guarantee terms, please contact your distributor.

5. EC Declaration of conformity

Naggura treatment tables are only meant to be used by professional personnel in physiotherapy, rehabilitation, examination, mas-

sage and aesthetics fields.

It is the responsibility of the owner to ensure that training is given to all operators and third parties (like for example cleaning per-

sonnel) on safe use of the treatment table, and that they have read and understood all the operating and safety instructions. 

Only trained operators may use the treatment bed. Please keep the manual in a place where it is easily accessible to all users, and 

make it an important part of your employee training program.

6. Safety instructions

Responsibility of the owner

- Place the table in a space with free access from the 4 sides. Do not place the table against the wall or against any obstacles. 

- Do not use the table in a high-humidity environment or in so-called “wet rooms” (hydrotherapy spaces). Any prolonged exposure to 

   high moisture conditions may affect the electrical components and may result in failure.

- Check the technical data and electrical parameters to ensure that the supply voltage meets the technical specifications of the 

   table. If not, contact your supplier before connecting the device.

- Make sure that the unit is correctly plugged into an earth intake, following the local and national requirements and standards.

- Make sure that the power cable is correctly and safely placed  in such a way that it cannot get trapped  between any mechanism. 

- Pay special attention that the supply cable does not get pinched under the feet of the table, (e.g. after having moved the table on  

   its wheels). 

- If the table accidentially gets wet, unplug it immediatelly.

- Do not leave chlidren unattended near the table. 

 

- Unless being monitored or instructed by personnel who can be responsible for their personal safety, the people who have physical  

   obstacles, tactile disorders, mental disorders, lack of experience, common sense or children, are not allowed to use the equipment.

- Do not use the device near electromagnetic transmitters. Read and follow all the information about electromagnetic compatibility  

   (EMC) in page 19.

- If the power cord or plug is damaged, please contact the distributor, service center or experienced technicians for reparing.

- Please pay attention that the continuous working times should be “Max.2Min. ON; 18Min. OFF”, when operating the motor. 

Safety on installation and electricity

Summary of Contents for Swop Physio

Page 1: ...Swop Physio Swop Physio VERSION 1 2 Treatment Tables for Physiotherapy SWOP2 SWOP2L SWOP2W SWOP3 SWOP5 Instruction Manual EN...

Page 2: ...atures Operation Wheel Block Unblock system Lever to adjust the headrest Breather hole and plug Handlebar support Hand controller Twinlift Space Ball perimeter foot switch Switches for lumbar flexion...

Page 3: ...will more than fulfil your most demanding work requirements NAGGURA s experts are in the lead of a project created with great devotion Every single detail has been cared to join technology performance...

Page 4: ...ts Naggura company is not liable for incidental or consequential damage to property or business 3 Warranty Under any circumstances the producer shall be liable for any indirect special incidental or c...

Page 5: ...er Place the table in a space with free access from the 4 sides Do not place the table against the wall or against any obstacles Do not use the table in a high humidity environment or in so called wet...

Page 6: ...table on a stable and horizontal surface Level it if necessary with the levelling feet under the table Guide the backrest section with the other hand when adjusting the backrest by gas levers Ensure...

Page 7: ...Instruction Manual 7 Swop 2 Swop 2L Swop 3 Swop 5 Swop 2W 7 Product dimensions...

Page 8: ...Instruction Manual 8 Handling and transport...

Page 9: ...m 250 cm Lateral displacement cm Power cord length cm Product dimensions Voltage and frequency input shall be 220 240V 50 60Hz Plug the table cable into the socket as shown below 8 Operation Power inp...

Page 10: ...g 4 Handlebar support 5 Twinlift 6 Space Ball perimeter foot switch 7 Switches for lumbar flexion 8 Lever to adjust the backrest 9 Paper roll holder 10 Side widening supports 11 Safety lock 12 Interch...

Page 11: ...oints are part of the same platform located under the table base The Space Ball perimeter switch works as follows if the therapist is located in one side of the table pull or push the activating point...

Page 12: ...nt temperature 0 C 40 C Relative humidity 30 90 Loading capacity 200 Kg Specifications 7 Switches for lumbar flexion If your Swop is a 2 engine table Swop3 and Swop5 the middle section lumbar flexion...

Page 13: ...e is locked and all the electrical systems are disabled The safety key can only be removed when the safety lock is in OFF position All SWOP physio models are fitted with a motor with an automatic clut...

Page 14: ...mood or however you feel today The exchangeable panels are 2 units one for one side of the table base and the other for its opposite The available panels are made of different materials metal wood and...

Page 15: ...Mood is installed an additional hand controller is provided to select your beloved colour to adjust the intensity of light or to change the lighting mode LED lighting Cromo Mood If you purchased the B...

Page 16: ...e is cleaned every day Clean the en tire surface using a mixture of 1 9 liquid soap neutral PH and water Do not use soap or cleaning solutions that contain alcohol ketones xylene acetates or solvents...

Page 17: ...is shown in the picture to turn the bed to one side without da maging the Space Ball perimeter switch Take the decorative panel in the base out and screw the L shaped plates in the same threaded holes...

Page 18: ...me operation with the second gas lift The up and down motor does not work Check if the power cable is disconnected either from the wall socket or the control box Check the power cable for any damage C...

Page 19: ...rade if proper distance is not maintained Guidance and Manufacturer s Declaration Electromagnetic Immunity Immunity Test IEC 60601 1 2 Test level Compliance level Electrostatic discharge ESD IEC 61000...

Page 20: ...28 V m 28 V m 710 MHz 745 MHz 780 MHz Pulse Modulation 217Hz 0 2W 9 V m 9 V m 810 MHz 870 MHz 930 MHz Pulse Modulation 18Hz 2W 28 V m 28 V m 1720 MHz 1845 MHz 1970 MHz Pulse Modulation 217Hz 2W 28 V m...

Page 21: ...Instruction Manual 21 Our products are subject to continuous technical improvements Naggura reserves the right to change or modify the product and contents without prior notice...

Page 22: ...www naggura com Pol Ind La Valldan Cam de Garreta 92 08600 Berga Barcelona Spain T 34 93 824 90 20 E info naggura com...

Reviews: