Returning Instrument for Service  

 

When  returning  the  instrument  to  the  manufacturer  for 

service,  please  provide  complete  information  about  the 

problems  faced  for  clear  analysis  of  the  problem.  The 

calibrator should be returned in the original packing. 

 

Nagman‘s liability ceases if :  

 

 

Parts are replaced / repaired using spare parts which are 

not identical to those recommended by the 

manufacturer. 

 

Nagman‘s liability is restricted to errors that originated from 

the factory. 

 

 

 

 

 

 

 

For more details, write to : 

NAGMAN INSTRUMENTS AND ELECTRONICS  

PRIVATE LIMITED 

170/1a2, Chennai Bangalore Highway Road, 

Sembarambakkam, 

Chennai - 600 123. INDIA. 

Phone: +91-44-66777000, 011, 022, 033 

Email: support@nagman.com  

Website : www.nagman.com 

Summary of Contents for HHP 700

Page 1: ...Nagman HYDRAULIC HAND PUMP HHP 700 1000...

Page 2: ...ince 1972 serving Industries in India Worldwide thro the Manufacture Supply of World Class Calibration Instruments Systems like Temperature Pressure Signal Calibrators Black Body Calibration Sources P...

Page 3: ...ck to correct any errors noticed and to improve the quality of contents of this Manual Specifications are subject to change owing to continuous development and we reserve rights to effect Changes Modi...

Page 4: ...No Description Page No 1 Introduction 5 2 Specification 6 3 Standard Delivery Optional Accessories 7 4 Parts Identification 8 5 Connection Diagram 9 6 Safety Instructions 10 7 Operating Instructions 1...

Page 5: ...rce for calibrating pressure transmitters pressure transducers and pressure gauges There is a Low High pressure selector switch in the pump which is used for selecting low high pressure output It is f...

Page 6: ...dicator Connection Port 3 8 F BSP Test Connection Port 1 4 F BSP Medium Oil Water Optional Oil Reservoir Material Transparent Acrylic Reservoir Capacity 100 cc Stabilization time 15 20 minutes Instrum...

Page 7: ...icate Instruction Manual Optional Accessories Carrying Case Soft Hard Analog Digital Pressure Gauges Quick Connector Spare Seals Kit Hydraulic Hose with end fittings Length 1 Meter Water operated Hand...

Page 8: ...r to Master Instrument 2 Pressure Release Valve 3 Fine Adjustment Valve 4 Front Port 1 4 BSP female 5 Reservoir 6 Reservoir Filling Plug Safety valve 7 Low High Pressure Selector 8 Fluid Inlet tube 9...

Page 9: ...NAG IM HHP 1000 01 22 9 5 CONNECTION DIAGRAM 1 Master Reference Measurement 2 Unit Under Test...

Page 10: ...NAG IM HHP 1000 01 22 10...

Page 11: ...ure drop due to thermodynamic effects setting of seals and expansion of pressure measuring hose As soon as dirt is noticed change the oil Do not release maximum pressure using Pressure release valve b...

Page 12: ...losed in clockwise direction Operate fine adjustment valve 3 bring it to mid position in anti clockwise direction Fully squeeze handles 10 in and turn Low High pressure selector 7 to low position The...

Page 13: ...ssure and then change the selector position to high for generating required maximum pressure depends on model Generate the remaining pressure using fine adjustment valve by turning it in clock wise di...

Page 14: ...pumping Check for any leak at all port connections and ensure for no trace of oil leak at connection ports Check that the Release Valve is fully closed Pump servicing work should be carried out only...

Page 15: ...nal packing Nagman s liability ceases if Parts are replaced repaired using spare parts which are not identical to those recommended by the manufacturer Nagman s liability is restricted to errors that...

Reviews: