6
Nagra –
CLASSIC DAC
Powering the CLASSIC DAC
The CLASSIC DAC can be powered either by its own internal power supply or by
an external 12 V DC power supply the Nagra MPS.
In the first case, simply use the provided mains AC cable.
Connecting the mains
Place the front panel selector in the OFF position, noted
O
. Insert the IEC cable
into the connector of the Nagra CLASSIC DAC.
You may then push the mains switch into the
I
position.
Fuse replacement
The fuse holder includes a
replacement fuse.
The fuse type is
FST 5x20mm
250V / T 500mA L
.
.
Should you need to replace it, only
use the same fuse type.
Connecting the Nagra MPS
Start by removing the IEC cable from its plug. The mains
switch position is no longer relevant when an external power
supply is connected.
Please note that the LEMO plug features a red dot that must
be facing upwards for correct insertion into the power input
connector.
Place the front panel selector in the
OFF
position. Insert the
LEMO plug from the external power supply into the DC
connector as shown above.
You will hear a click, indicating that the plug is securely
locked in.
You should connect the BLACK tail cable on the MPS side.
To disconnect the LEMO plug. Hold the fluted section of the plug as shown in the
picture and pull backwards.