Input setting
The Nagra CLASSIC PHONO is supplied with a Phono stage for Moving Magnet
(MM) cartridges positioned on the input PHONO 2 and a Phono stage for
Moving Coil (MC) cartridges positioned on the input PHONO 1.
Optionally, you can obtain an other MM or MC Phono module to place on the
desired input. Please contact your Nagra dealer for more information.
Note:
Please switch off (front rotary selector & Mains switch) your Nagra
CLASSIC PHONO and disconnect its power cable (Mains or external DC
power supply), at least 10 minutes, before opening the top panel to perform
any changes or adjustments on the input modules.
Open/close the Nagra CLASSIC PHONO
Remove the eight screws
from the top panel of the
Nagra CLASSIC PHONO
with the supplied Allen key
(2.5 mm). Then vertically
lift up the top panel to
open the device.
When closing the device,
make sure you place the top
panel correctly, so that the
eight fixing screws can be
tightened (no screws above
the front panel). The two
hollowed out internal parts of
the top panel will be in the
right positions to avoid any
damages to the tubes and the
electronic components.