10
Nagra –
Classic PSU
Starting the CLASSIC PSU using the trigger input
On the
R
position, you can start the CLASSIC
PSU using the REM (for REMote) input.
Please note that both the tip and the sleeve of
the 1/8” Jack should be connected to the ground.
Signal on the ring
CLASSIC PSU
Connected to the ground
Off
Open or connected to max 12 V
On
Whenever you connect a jack on the REM connector, it will override the Infra Red
remote control.
Using the trigger outputs
See the following picture for cabling of the 1/8” jack.
CLASSIC PSU
Tip and ring
AMP On
Connected
AMP Off
Open
The outputs will be activated at the end of the powering sequence, to avoid any
clicks that sometimes occur at start-up. When powering down, these outputs will
be turn off first.
Case cleaning
Clean the CLASSIC PSU casing using a soft, non-fluffy, slightly damp cloth. Do
not use any cleaning products which could have a corrosive effect.